Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Robotic-assisted surgery has improved the precision and accuracy of surgical movements with subsequent improved outcomes. However, it requires steep Trendelenburg positioning combined with pneumoperitoneum that negatively affects respiratory mechanics and increases the risk of postoperative respiratory complications. This narrative review summarises the state of the art in ventilatory management of these patients in terms of levels of positive end-expiratory pressure (PEEP), tidal volume, recruitment manoeuvres, and ventilation modes during both urological and gynaecological robotic-assisted surgery. A review of the literature was conducted using PubMed/MEDLINE; after completing abstract and full-text review, 31 articles were included. Although different levels of PEEP were often evaluated within a protective ventilation strategy, including higher levels of PEEP, lower tidal volume, and recruitment manoeuvres vs a conventional ventilation strategy, we conclude that the best PEEP in terms of lung mechanics, gas exchange, and ventilation distribution has not been defined, but moderate PEEP levels (4-8 cm HO) could be associated with better outcomes than lower or highest levels. Recruitment manoeuvres improved intraoperative arterial oxygenation, end-expiratory lung volume and the distribution of ventilation to dependent (dorsal) lung regions. Pressure-controlled compared with volume-controlled ventilation showed lower peak airway pressures with both higher compliance and higher carbon dioxide clearance. We propose directions to optimise ventilatory management during robotic surgery in light of the current evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bja.2023.06.066 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!