A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Attempt to read property "Count" on bool

Filename: helpers/my_audit_helper.php

Line Number: 3100

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Defining optimal thresholds for digital Brix refractometry to determine IgG concentration in ewe colostrum and lamb serum in Scottish lowland sheep flocks. | LitMetric

Defining optimal thresholds for digital Brix refractometry to determine IgG concentration in ewe colostrum and lamb serum in Scottish lowland sheep flocks.

Prev Vet Med

School of Biodiversity, One Health and Veterinary Medicine, University of Glasgow, 464 Bearsden Road, Bearsden, Glasgow G61 1QH, United Kingdom.

Published: September 2023

This research aimed to define thresholds for ewe colostrum and lamb serum Brix refractometer measurements in lowland Scottish sheep. This would facilitate the use of this convenient, sheep-side test, enabling quick and accurate identification of poor quality colostrum and prevention of failure of transfer of passive immunity (FTPI) in lambs. Secondary aims were to identify risk factors for poor colostrum quality and FTPI in lambs. Serum samples (n = 233) were collected from lambs between 24 and 48hrs after birth, from four lowland Scottish meat sheep farms. Pre-suckle colostrum samples (n = 112) were also collected from ewes on two of these farms. Farmers provided information on litter size, ewe body condition score, ewe breed and dystocia. Duplicate digital Brix refractometer measurements were compared with immunoglobulin G (IgG) radial immunodiffusion (RID) testing for all colostrum and serum samples. Receiver operating characteristic (ROC) curves were used to redefine thresholds for Brix testing in colostrum and serum. Linear regression models were constructed with colostrum and serum IgG concentration as the outcomes of interest. Colostrum and serum IgG concentrations were highly variable. The prevalence of inadequate colostrum quality (using <50 g/L IgG on RID) was 4.5% (95% CI = 1.5 - 10.1) and the prevalence of FTPI (using <15 g/L IgG in serum on RID) was 7.73% (95% CI = 4.64-11.93). A ewe's colostrum IgG concentration was significantly and positively associated with the serum IgG concentration of her lamb(s) (p = 0.02). ROC analysis defined a Brix threshold for adequate colostrum quality of > 22.10% (sensitivity 80% (95%CI=28.4-99.5), specificity 90% (95%CI=82.3-94.8)). ROC analysis defined a Brix threshold for serum of > 8.65% for adequate passive transfer of immunity in Scottish lambs (sensitivity 94% (95%CI=72.7-99.8), specificity 82% (95%CI=76.6-87.2)). To optimise passive transfer of immunity in lambs, we suggest that ewe colostrum Brix measurements be defined as 'poor' (<22%); 'fair' (22-26%) and 'good' (>26%); and lamb serum as 'poor' (<8%); 'fair' (8-9%) and 'good' (>9%). It is recommended that these tests are used as for flock screening, using samples from multiple animals.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prevetmed.2023.105988DOI Listing

Publication Analysis

Top Keywords

colostrum serum
16
colostrum
10
digital brix
8
igg concentration
8
ewe colostrum
8
colostrum lamb
8
lamb serum
8
brix refractometer
8
refractometer measurements
8
lowland scottish
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!