Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Scaphoid waist fractures are the most common fracture of the scaphoid. Operative management is indicated with unstable fractures and often for nondisplaced waist fractures to decrease time to union and return to work/sport. Screw placement within the central axis of the scaphoid is paramount and correlates with outcomes. Assessment of intrascaphoid screw placement is classically done via intraoperative fluoroscopy. An additional fluoroscopic view is presented to assist in confirming implant positioning. Along with the standard anterioposterior, lateral, pronated oblique, and "scaphoid" view we obtain a "standing peanut" view for assessment of central screw placement. This view also allows for further evaluation of center/center positioning and better assessment of fixation crossing the fracture into the proximal pole. The "standing peanut" view is best obtained in a sequential manner beginning with the forearm in neutral rotation. First, the forearm is then supinated 30 degrees; next, the wrist is placed at 45 degrees of ulnar deviation. Then finally, 10 degrees of wrist extension. We utilize this additional intraoperative view in conjunction with the standard fluoroscopic views for assessing and ensuring center-center implant positioning, particularly within the proximal pole. When ensuring center-center positioning, we prefer this view as an adjunct view to the standard fluoroscopic views intraoperatively. It provides a beneficial view of the proximal pole delineating the number of screw threads that have obtained proximal pole purchase. We have found it particularly useful in the setting of scaphoid waist fracture nonunion with the classic 'humpback' deformity after correction with volar interposition grafting. Standard radiographic views may be misinterpreted regarding implant positioning if there remains any residual flexion. The view requires little in the way of training to obtain once appreciated and exposes the patient to minimal additional radiation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BTH.0000000000000447 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!