This report provides guidance for the implementation of online treatment monitoring (OTM) solutions in radiotherapy (RT), with a focus on modulated treatments. Support is provided covering the implementation process, from identification of an OTM solution to local implementation strategy. Guidance has been developed by a RT special interest group (RTSIG) working party (WP) on behalf of the Institute of Physics and Engineering in Medicine (IPEM). Recommendations within the report are derived from the experience of the WP members (in consultation with manufacturers, vendors and user groups), existing guidance or legislation and a UK survey conducted in 2020 (Stevens2021). OTM is an inclusive term representing any system capable of providing a direct or inferred measurement of the delivered dose to a RT patient. Information on each type of OTM is provided but, commensurate with UK demand, guidance is largely influenced bydosimetry methods utilising the electronic portal imager device (EPID). Sections are included on the choice of OTM solutions, acceptance and commissioning methods with recommendations on routine quality control, analytical methods and tolerance setting, clinical introduction and staffing/resource requirements. The guidance aims to give a practical solution to sensitivity and specificity testing. Functionality is provided for the user to introduce known errors into treatment plans for local testing. Receiver operating characteristic analysis is discussed as a tool to performance assess OTM systems. OTM solutions can help verify the correct delivery of radiotherapy treatment. Furthermore, modern systems are increasingly capable of providing clinical decision-making information which can impact the course of a patient's treatment. However, technical limitations persist. It is not within the scope of this guidance to critique each available solution, but the user is encouraged to carefully consider workflow and engage with manufacturers in resolving compatibility issues.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/acecd0DOI Listing

Publication Analysis

Top Keywords

otm solutions
12
report guidance
8
implementation online
8
online treatment
8
treatment monitoring
8
capable providing
8
guidance
7
otm
7
treatment
5
ipem topical
4

Similar Publications

Background: Wide QRS complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) remains challenging despite numerous 12-lead electrocardiogram (ECG) criteria and algorithms. Automated solutions leveraging computerized ECG interpretation (CEI) measurements and engineered features offer practical ways to improve diagnostic accuracy. We propose automated algorithms based on (i) WCT QRS polarity direction (WCT Polarity Code [WCT-PC]) and (ii) QRS polarity shifts between WCT and baseline ECGs (QRS Polarity Shift [QRS-PS]).

View Article and Find Full Text PDF

The effects of luteolin on orthodontic tooth movement and relapse.

Am J Orthod Dentofacial Orthop

November 2024

Department of Orthodontics, School and Hospital of Stomatology, China Medical University, Shenyang Clinical Medical Research Center of Orthodontic Disease, Shenyang, Liaoning Province, China. Electronic address:

Introduction: Luteolin is a natural flavonoid compound that widely exists in human food. Studies have demonstrated luteolin has powerful anti-inflammatory properties and can affect bone remodeling in an inflammatory environment. This study aimed to investigate the effect of luteolin on orthodontic tooth movement (OTM) and relapse after OTM.

View Article and Find Full Text PDF

Background The use of platelet-rich plasma (PRP) in dentistry was entered several decades ago, yet its clinical use in orthodontics still requires further investigation. The aim of this study was to evaluate the possible effects of local injection of PRP on the rate and type of mandibular second molar protraction movement compared with the comparator (no PRP) group. Material and methods Eighteen patients aged between 17 and 25 years were randomly allocated in a split-mouth study design to receive PRP injections on one side immediately before the start of molar protraction (PRP group), while the other side received only saline solution (comparator group).

View Article and Find Full Text PDF

Successful cryopreservation in biodegradable containers of sperm from aquaculture Mediterranean fishes.

Theriogenology

March 2024

Grupo de Acuicultura y Biodiversidad, Instituto de Ciencia y Tecnologia Animal, Universitat Politècnica de València, Edificio 7G, Camino de Vera s/n, 46022, Valencia, Spain. Electronic address:

We aimed to evaluate the efficiency of hard-gelatin and hard-hydroxypropyl methylcellulose (HPMC) capsules as biodegradable alternative containers to plastic straws in European eel (Anguilla anguilla), gilthead seabream (Sparus aurata) and European sea bass (Dicentrarchus labrax) sperm cryopreservation. Sperm samples from each European eel (n = 12) were diluted 1:8:1 (sperm: extender P1+5 % egg yolk: methanol). Gilthead seabream (n = 12) samples were individually diluted in a cryoprotectant solution of 5 % MeSO + NaCl 1 % plus BSA (10 mg mL) at a ratio of 1:6 (sperm: cryoprotectant solution).

View Article and Find Full Text PDF

This report provides guidance for the implementation of online treatment monitoring (OTM) solutions in radiotherapy (RT), with a focus on modulated treatments. Support is provided covering the implementation process, from identification of an OTM solution to local implementation strategy. Guidance has been developed by a RT special interest group (RTSIG) working party (WP) on behalf of the Institute of Physics and Engineering in Medicine (IPEM).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!