A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Nucleoside hydrolase immobilized on magnetic particles as a tool for onflow screening and characterization of inhibitors. | LitMetric

Nucleoside Hydrolases (NH) are considered a target for the development of new antiprotozoal agents. The development of new and automated screening assays for the identification of NH inhibitors can accelerate the first stages of the drug discovery process. In this work, NH from Leishmania donovani (LdNH) was covalently immobilized onto magnetic particles (LdNH-MPs) and trapped by magnets into a TFE tube to yield an immobilized enzyme reactor (IMER). For an automated assay, the LdNH-MP-IMER was connected in-line to an analytical column in an HPLC-DAD system to monitor the enzyme activity through quantification of the product hypoxanthine. Kinetic studies provided a K value of 2079 ± 87 µmol.L for the inosine substrate. Validation of the LdNH-MP-IMER for onflow screening purposes was performed with a library containing 12 quinolone ribonucleosides. Among them, three were identified as new competitive LdNH inhibitors, with K values between 83.5 and 169.4 µmol.L. This novel in-line screening assay has proven to be reliable, fast, low cost, and applicable to large libraries of compounds.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2023.115589DOI Listing

Publication Analysis

Top Keywords

immobilized magnetic
8
magnetic particles
8
onflow screening
8
nucleoside hydrolase
4
hydrolase immobilized
4
particles tool
4
tool onflow
4
screening
4
screening characterization
4
characterization inhibitors
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!