Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the efficacy of YOUSOFT soft contact lenses in correcting irregular astigmatism and prescription results of patients with keratoconus.
Patients And Methods: The retrospective observational study included 55 eyes (mean age, 32.2 ± 10.6 years; 36 men and 6 women) of 42 patients with keratoconus who tried YOUSOFT for rigid gas permeable (RGP) lens intolerance. Average keratometry, corneal astigmatism, and maximum keratometry were 49.4 ± 5.2 diopters (D), 3.7 ± 2.1 D, and 57.3 ± 8.2 D, respectively. Patients were divided into YOUSOFT prescription and non-prescription cases, wherein the prescription rates were calculated. YOUSOFT visual acuity was compared with spectacle-corrected distance visual acuity (CDVA) and RGP lens-CDVA.
Results: YOUSOFT was prescribed to 28 out of 42 patients (prescription rate 67%). In the YOUSOFT prescription cases, YOUSOFT-CDVA (logMAR -0.04; 95% confidence interval [CI]: -0.08 to 0.00) was significantly better than spectacle-CDVA (logMAR 0.23; 95% CI: 0.08 to 0.38; P < 0.0001), whereas YOUSOFT-CDVA (logMAR -0.03; 95% CI: -0.08 to 0.03) did not significantly differ from the RGP lens-CDVA (logMAR -0.02; 95% CI: -0.08 to 0.04; P = 0.856).
Conclusion: YOUSOFT was effective in correcting irregular corneal astigmatism, suggesting that it is highly effective in patients with RGP lens intolerance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10389083 | PMC |
http://dx.doi.org/10.2147/OPTH.S420940 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!