A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spectral correction of light emitting diodes enables accurate hydration ratio calculation using narrowband diffuse reflectance spectroscopy. | LitMetric

Significance: Light emitting diodes (LEDs) are commonly utilized for tissue spectroscopy due to their small size, low cost, and simplicity. However, LEDs are often approximated as single-wavelength devices despite having relatively broad spectral bandwidths. When paired with photodiodes, the wavelength information of detected light cannot be resolved. This can result in errors during chromophore concentration calculations. These errors are particularly apparent when analyzing water and fat in the 900 to 1000 nm window where the spectral bandwidth of LEDs can encompass much of the analysis region, resulting in intense crosstalk.

Aim: We utilize and present a spectral correction (SC) algorithm to correct for the spectral bandwidth of LEDs. We show the efficacy using a narrowband technique of spectrally broad and overlapping LEDs.

Approach: Narrowband diffuse reflectance spectroscopy (nb-DRS), a technique capable of quantifying the hydration ratio () of turbid media, was utilized. nb-DRS typically requires a broadband light source and spectrometer. We reduce the hardware to just five LEDs and a photodiode detector, relying on SC to compensate for spectral crosstalk. The effectiveness of our SC approach was tested in simulations as well as in an emulsion phantom and limited selection of human tissue.

Results: In simulations, we show that calculated errors increased with the spectral bandwidth of LEDs but could be corrected using SC. Likewise, in emulsions, we found an average error of 8.7% (maximum error 14%) if SC was not used. By contrast, applying SC reduced the average error to 2.2% (maximum error of 6.4%). We show that despite utilizing multiple, spectrally broad, and overlapping LEDs, SC was still able to restore the performance of our narrowband method, making it comparable to a much larger full broadband system.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10387445PMC
http://dx.doi.org/10.1117/1.JBO.28.7.075005DOI Listing

Publication Analysis

Top Keywords

spectral bandwidth
12
bandwidth leds
12
spectral correction
8
light emitting
8
emitting diodes
8
hydration ratio
8
narrowband diffuse
8
diffuse reflectance
8
reflectance spectroscopy
8
spectrally broad
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!