Data-independent acquisition (DIA) mass spectrometry has grown in popularity in recent years, because of the reproducibility and quantitative rigor of a systematic tandem mass spectrometry (MS/MS) sampling method. However, traditional DIA methods may spend valuable instrument time acquiring MS/MS spectra with no usable information in them, affecting sensitivity and quantitative performance. We developed a DIA strategy that dynamically adjusts the MS/MS windows during the chromatographic separation. The method focuses MS/MS acquisition on the most relevant mass range at each point in time─increasing the quantitative sensitivity by increasing the time spent on each DIA window. We demonstrate an improved lower limit of quantification, on average, without sacrificing the number of peptides detected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10517878PMC
http://dx.doi.org/10.1021/acs.analchem.3c00903DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
12
data-independent acquisition
8
dynamic data-independent
4
mass
4
acquisition mass
4
spectrometry real-time
4
real-time retrospective
4
retrospective alignment
4
alignment data-independent
4
dia
4

Similar Publications

In recent years, alternative enzymes with varied specificities have gained importance in MS-based bottom-up proteomics, offering orthogonal information about biological samples and advantages in certain applications. However, most mass spectrometric workflows are optimized for tryptic digests. This raises the questions of whether enzyme specificity impacts mass spectrometry and if current methods for nontryptic digests are suboptimal.

View Article and Find Full Text PDF

A charge-tagged N-heterocyclic carbene (NHC) has been synthesized and its utility in allowing the dynamic behaviour of metal complexes to be monitored in real time using electrospray ionization mass spectrometry demonstrated. This compound was used to prepare different metal-NHC complexes, and the kinetic behaviour of complex formation and ligand exchange was monitored in real time through the use of pressurized sample infusion electrospray mass spectrometry (PSI-ESI-MS).

View Article and Find Full Text PDF

Desalting of oligonucleotides through precipitation for mass spectrometric analysis.

Nucleosides Nucleotides Nucleic Acids

January 2025

Department of Chemistry and Centre for Biotechnology, Brock University, St. Catharines, ON, Canada.

Contamination of sodium ions in oligonucleotides often causes issues in mass spectrometric analysis. This study investigated the efficiency of the combination of ammonium acetate and alcohol in desalting oligonucleotides. It was found that oligonucleotide samples containing up to 4 M NaCl can be effectively desalted through precipitation with ethanol or isopropanol in the presence of 1 or 5 M ammonium acetate.

View Article and Find Full Text PDF

Dynamin-related protein 1 (Drp1) is a mitochondrial fission protein and a viable target for cardioprotection against myocardial ischaemia-reperfusion injury. Here, we reported a novel Drp1 inhibitor (DRP1i1), delivered using a cardiac-targeted nanoparticle drug delivery system, as a more effective approach for achieving acute cardioprotection. DRP1i1 was encapsulated in cubosome nanoparticles with conjugated cardiac-homing peptides (NanoDRP1i1) and the encapsulation efficiency was 99.

View Article and Find Full Text PDF

Hypertension, a major cause of cardiomyopathy, is one of the most critical risk factors for heart failure and mortality worldwide. Loss of metabolic flexibility of cardiomyocytes is one of the major causes of heart failure. Although Catestatin (CST) treatment is known to be both hypotensive and cardioprotective, its effect on cardiac metabolism is unknown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!