Objectives: To assess intra-individually visual acuity (VA) and subjective outcome after mix-and-match implantation of a monofocal EDOF IOL and a diffractive trifocal IOL.
Methods: The monofocal EDOF Isopure IOL was implanted in the dominant eye and the trifocal FineVision HP IOL in the non-dominant eye. Postoperative evaluation included VA at various distances, contrast acuity, monocular defocus curves, decentration and tilt, wavefront aberrometry, VF-7 questionnaire and a halo and glare simulator.
Results: 50 eyes of 25 subjects were enroled. The trifocal IOL performed better at monocular DCNVA (p < 0.01) and at defocus levels of -1.5D to -4.0D (p < 0.01), the monofocal EDOF IOL was better at -0.5D (p = 0.013). No differences in monocular BCDVA, DCIVA, contrast acuity, decentration or tilt were observed (p > 0.05). Wavefront analysis revealed lower HOAs in the trifocal group at 5 mm (p < 0.01) and no difference (p = 0.107) at 3 mm pupil aperture. The monofocal EDOF IOL displayed increased negative SA at 5 mm (p < 0.01) and 3 mm (p < 0.01) pupil diameter. Low values of optical phenomena and satisfying results of the VF-7 questionnaire were obtained.
Conclusion: Excellent visual performance and low rates of optical phenomena were achieved after mix-and-match implantation of the monofocal EDOF Isopure IOL and the trifocal FineVision HP IOL. Trifocal IOL implantation in the non-dominant eye may decrease optical disturbing phenomena. Similar results were observed for monocular distance, intermediate and contrast VA. The trifocal IOL provided better monocular near VA. Decentration and tilt and HOAs were low.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10811191 | PMC |
http://dx.doi.org/10.1038/s41433-023-02682-x | DOI Listing |
Sci Rep
December 2024
Imaging, Biomechanics and Mathematical Modelling Solutions Lab, Narayana Nethralaya Foundation, Bangalore, India.
An induced cylinder and spherical power after implantation with an extended depth of focus (EDOF) and enhanced monofocal intraocular lens (IOL) could improve distance, intermediate (60 cm) and near (40 cm) visual acuity (VA). In this prospective study, forty eyes with Eyhance EDOF IOL (Johnson and Johnson, USA) and 40 eyes with Vivity EDOF IOL (Alcon Laboratories Inc. USA) were included.
View Article and Find Full Text PDFBiomed Opt Express
December 2024
Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, 30100 Murcia, Spain.
Cataract surgery involves the implantation of an intraocular lens (IOL) to replace the opacified crystalline lens. Monofocal IOLs, the most common type, are intended to have the eye in focus at a given distance, usually at infinity. Simultaneous vision IOLs (SVIOLs) and extended depth of focus (EDOF) aim to minimize postoperative dependence on spectacles by providing either multiple foci or an extended depth of focus.
View Article and Find Full Text PDFBr J Ophthalmol
December 2024
Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
Biomed Opt Express
November 2024
Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain.
This study presents a systematic method to simulate various intraocular lenses (IOLs) available in the market. Five IOLs (two trifocals, one bifocal, one enhanced monofocal, and one extended depth of focus (EDOF)) were evaluated in terms of through focus visual Strehl (TFVS) utilizing the OptiSpheric IOL PRO2 device (Trioptics GmbH). Then, the estimated TFVS (ETFVS) and the temporal coefficients necessary for temporal multiplexing were computed, and through an iterative process, the SimVis TFVS was obtained.
View Article and Find Full Text PDFInt Ophthalmol
November 2024
Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama City, 930-0194, Japan.
Purpose: We investigated the effect of enhanced monofocal intraocular lenses (IOL) (TECNIS Eyhance DIB00V) on retinal sensitivity in glaucoma patients after cataract surgery by comparing results with of such patients implanted with non-enhanced monofocal intraocular lenses (TECNIS ZCB00V).
Patients And Methods: This was a multi-facility retrospective study of glaucoma patients who had undergone cataract surgery. We measured the value of the foveal threshold with a Humphrey visual field analyzer before and after cataract surgery and considered this value to represent the sensitivity of the retina.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!