Aim: The purpose of this retrospective study was to compare, among various implant systems, the influence of primary stability and the bone density and soft tissue biotype of the patient on the amount of peri-implant crestal bone loss after 1 year using radiography.
Materials And Methods: Included in this retrospective study were patient records of 3583 implant placements utilized from an online dental information archiving software (DIAS). Clinical and radiographic assessments were conducted concurrently with implant placement (baseline) and 1 year post surgery. Statistical analysis was done to examine the mean marginal bone loss significance in the three different implant systems groups (group I: Straumann Roxolid SLAc-tive, group II: Nobel Biocare CC, group III: Straumann SLA), different primary stability values, different bone density. and soft tissue biotype at the time of implant placement.
Results: A significant difference was observed in the crestal bone loss with different implant systems used. Group I showed significantly lesser amounts of crestal bone loss when compared to groups II and III. However, the differences in the bone density, ISQ values, and the soft tissue biotype did not exhibit a statistically significant difference in the amount of crestal bone loss.
Conclusion: Significant MBL preservation for implants with Straumann SLActive when compared to Nobel Biocare CC and Straumann SLA implants. No significant changes were observed with respect to primary stability, bone density, and soft tissue thickness and no correlation among early crestal bone loss and IT, ISQ at surgery, and ISQ at reopening was observed. Straumann Roxolid SLActive implants showed less crestal bone loss probably owing to its hydrophilic surface modification. However, more studies need to be done to evaluate the same.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1615/JLongTermEffMedImplants.2022042617 | DOI Listing |
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics, K M Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).
Setting And Design: In vitro (in silico study) finite element analysis (FEA).
Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.
J Biomed Mater Res A
January 2025
Research and Development, ZimVie Dental, Palm Beach Gardens, Florida, USA.
Dental implant coronal surfaces designed with the primary goal of maintaining crestal bone levels may also promote bacterial adhesion, leading to soft tissue inflammation and peri-implant bone loss. Achieving an optimal surface roughness that minimizes bacterial adhesion while preserving crestal bone is crucial. It is hypothesized that a specific threshold surface roughness value may exist below which, and above which, initial bacterial adhesion does not statistically change.
View Article and Find Full Text PDFImaging Sci Dent
December 2024
Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Assiut University, Assiut, Egypt.
Purpose: This study was performed to introduce, evaluate, and compare various novel assessment protocols designed for straightforward, reliable, and reproducible measurement of alveolar bone levels. These protocols are intended for standardized periodontal assessment and follow-up, utilizing cone-beam computed tomography (CBCT) images and manipulation of Digital Imaging and Communications in Medicine (DICOM) viewer software.
Materials And Methods: Two experienced oral and maxillofacial radiologists developed 5 distinct radiographic measurement protocols.
J Indian Soc Periodontol
December 2024
Department of Periodontology and Implantology, G. Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India.
Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.
Materials And Methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)).
J Indian Soc Periodontol
December 2024
Department of Periodontics, MGV's KBH Dental College and Hospital, Nashik, Maharashtra, India.
Introduction: Following tooth extraction, there is comparatively more bone loss at the buccal aspect at 3 months of healing, which may result in 56% bone loss due to resorption of the bucco-facial ridge contour. In the socket shield technique, a tooth is planned for extraction in such a way that the tooth is sectioned in two halves, a palatal section is removed and the facial part is retained.
Materials And Methods: Twenty-six sites, i.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!