Evaluation of Peri-Implant Crestal Bone Loss with Different Implant Systems, Primary Stability, Bone Density and Soft Tissue Thickness: A Retrospective Study.

J Long Term Eff Med Implants

Department of Prosthodontics and Implantology, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai-600077, Tamil Nadu, India.

Published: January 2023

Aim: The purpose of this retrospective study was to compare, among various implant systems, the influence of primary stability and the bone density and soft tissue biotype of the patient on the amount of peri-implant crestal bone loss after 1 year using radiography.

Materials And Methods: Included in this retrospective study were patient records of 3583 implant placements utilized from an online dental information archiving software (DIAS). Clinical and radiographic assessments were conducted concurrently with implant placement (baseline) and 1 year post surgery. Statistical analysis was done to examine the mean marginal bone loss significance in the three different implant systems groups (group I: Straumann Roxolid SLAc-tive, group II: Nobel Biocare CC, group III: Straumann SLA), different primary stability values, different bone density. and soft tissue biotype at the time of implant placement.

Results: A significant difference was observed in the crestal bone loss with different implant systems used. Group I showed significantly lesser amounts of crestal bone loss when compared to groups II and III. However, the differences in the bone density, ISQ values, and the soft tissue biotype did not exhibit a statistically significant difference in the amount of crestal bone loss.

Conclusion: Significant MBL preservation for implants with Straumann SLActive when compared to Nobel Biocare CC and Straumann SLA implants. No significant changes were observed with respect to primary stability, bone density, and soft tissue thickness and no correlation among early crestal bone loss and IT, ISQ at surgery, and ISQ at reopening was observed. Straumann Roxolid SLActive implants showed less crestal bone loss probably owing to its hydrophilic surface modification. However, more studies need to be done to evaluate the same.

Download full-text PDF

Source
http://dx.doi.org/10.1615/JLongTermEffMedImplants.2022042617DOI Listing

Publication Analysis

Top Keywords

crestal bone
28
bone loss
28
bone density
20
soft tissue
20
implant systems
16
primary stability
16
density soft
16
bone
13
stability bone
12
retrospective study
12

Similar Publications

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.

View Article and Find Full Text PDF

Dental implant coronal surfaces designed with the primary goal of maintaining crestal bone levels may also promote bacterial adhesion, leading to soft tissue inflammation and peri-implant bone loss. Achieving an optimal surface roughness that minimizes bacterial adhesion while preserving crestal bone is crucial. It is hypothesized that a specific threshold surface roughness value may exist below which, and above which, initial bacterial adhesion does not statistically change.

View Article and Find Full Text PDF

Purpose: This study was performed to introduce, evaluate, and compare various novel assessment protocols designed for straightforward, reliable, and reproducible measurement of alveolar bone levels. These protocols are intended for standardized periodontal assessment and follow-up, utilizing cone-beam computed tomography (CBCT) images and manipulation of Digital Imaging and Communications in Medicine (DICOM) viewer software.

Materials And Methods: Two experienced oral and maxillofacial radiologists developed 5 distinct radiographic measurement protocols.

View Article and Find Full Text PDF

Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.

Materials And Methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)).

View Article and Find Full Text PDF

Introduction: Following tooth extraction, there is comparatively more bone loss at the buccal aspect at 3 months of healing, which may result in 56% bone loss due to resorption of the bucco-facial ridge contour. In the socket shield technique, a tooth is planned for extraction in such a way that the tooth is sectioned in two halves, a palatal section is removed and the facial part is retained.

Materials And Methods: Twenty-six sites, i.

View Article and Find Full Text PDF