A 60-year-old man who underwent uncomplicated staged bilateral total hip arthroplasty for femoral head osteonecrosis presented with mechanical catching of his left total hip arthroplasty 3 years after index surgery. Radiographs revealed eccentricity of the left femoral head, concerning the failure of a modern moderately cross-linked polyethylene liner. Catastrophic polyethylene liner failure with significant wear, fragmentation, and femoral head abrasion was noted during revision surgery. The original liner and head were replaced, and the patient has exhibited no complications, pain, or difficulty ambulating 6 months postoperatively. This report highlights one potential novel mechanism for the failure of the Exactech Connexion GXL liner (Exactech Inc., Gainesville, FL), an implant recently reported to have a higher-than-expected failure rate, potentially due to insufficient packaging and increased oxidative processes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10382623PMC
http://dx.doi.org/10.1016/j.artd.2023.101161DOI Listing

Publication Analysis

Top Keywords

femoral head
12
modern moderately
8
moderately cross-linked
8
cross-linked polyethylene
8
total hip
8
hip arthroplasty
8
polyethylene liner
8
failure
5
liner
5
catastrophic early
4

Similar Publications

Effect of head size, head material, and radiation dose on the repeatability of CT-RSA measurements of femoral head penetration.

J Mech Behav Biomed Mater

January 2025

Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada; Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada. Electronic address:

Background: The risk of early revision of total hip arthroplasty (THA) for polyethylene wear is now low, but there remains a need to perform wear measurements in patients for clinical surveillance. The gold standard of wear measurements has been radiostereometric analysis (RSA), which has limited availability. The use of computed tomography (CT) to perform THA wear measurement was described a decade ago and found to have acceptable accuracy and precision, but high radiation dose was a concern.

View Article and Find Full Text PDF

Deep venous thrombosis (DVT) represents a significant postoperative complication after artificial femoral head replacement, with the incidence increasing proportionally with patient age. This study aimed to evaluate the effect of early postoperative use of intermittent pneumatic compression devices (IPC), followed by the combined use of low molecular weight heparin (LMWH) after 48 hours, for the prevention of postoperative lower limb DVT in elderly patients undergoing hip arthroplasty. The retrospective study included 100 elderly patients who underwent unilateral femoral head replacement.

View Article and Find Full Text PDF

: Developmental dysplasia of the hip (DDH), defined by the malalignment of the femoral head and acetabulum, is a major precursor to coxarthrosis, posing substantial challenges during total hip arthroplasty (THA). Patients with coxarthrosis secondary to DDH often exhibit acetabular bone insufficiency, which makes challenging surgical reconstruction difficult. This study aimed to compare the radiologic and functional outcomes of robotically assisted and conventional manual THA techniques in patients with coxarthrosis secondary to Crowe type III-IV DDH.

View Article and Find Full Text PDF

The paper presents a detailed gross anatomical description of the elements of the pelvic limb in the African green monkey and provides comparative and differential elements on pelvic limb monkey osteology. The osteometric investigation adds value to the gross morphological and radiological investigation, adjoining metric data to the gross descriptive data set. The main methodology used was the gross morphological investigation, doubled by regular osteometrical and radiographical assessments.

View Article and Find Full Text PDF

Radiographic and Clinical Results of Combined Bone and Soft-Tissue Tailored Surgeries for Hip Dislocation and Subluxation in Cerebral Palsy.

Children (Basel)

January 2025

Department of Paediatric Surgery, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy.

Background/objectives: The aim of the study is to present middle-term results of tailored bone and soft-tissue surgeries in subluxated and dislocated hips in children affected by cerebral palsy.

Methods: A total of 87 medical records belonging to 73 children affected by CP, treated with combined soft-tissue releases, VDO, and pelvic osteotomy, were reviewed retrospectively. Radiological measurements of AI, RI, and NSA were obtained before surgery, postoperatively, at 12 and 24 months after surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!