Objective: It is important to guarantee intra-aneurysmal stability of microcatheters during coil embolization. We developed a simple and reproducible microcatheter shaping method for medially-directed paraclinoid internal carotid artery aneurysms.

Methods: An injection needle cap was used to make a smooth curve on the mandrel, which was first wound around the back end of the cap to create a primary curve. Next, a secondary curve was created using near the tip of the cap. Thus, a two-dimensional (2D), pigtail-shaped mandrel with a two-stage curve was created. The pigtail-shaped mandrel was inserted from the tip of a straight microcatheter and heat-shaped using a heat gun. Lastly, a microcatheter having a curve whose tip was approximately 6 mm longer than that of the preshaped J was created. We evaluated the ease of navigating the microcatheter into the aneurysm and its stability during coil embolization.

Results: In all, 34 consecutive medially-directed paraclinoid internal carotid artery aneurysms were treated using the shaped catheters. It took 50-300 seconds (intermediate value: 90 seconds) from inserting the microcatheter with a microguide wire to navigate and place it into an aneurysm. There were no cases that required reshaping of the microcatheters during navigation into the aneurysm. There were no cases that resulted in kickback of the microcatheters from the aneurysm during coil placement, and microcatheter stability was good until the end of the procedure. In all, 12 cases required the balloon-assisted technique and three cases required stent-assisted coiling. The angiographic outcomes immediately after embolization were as follows: 25 cases (73.5%) with complete occlusion; 3 cases (8.8%) with dome filling; and 6 cases (17.6%) with a neck remnant. There were no perioperative complications.

Conclusion: The shaping method with a pigtail-shaped mandrel using an injection needle cap is simple and reproducible, and is useful for medially-directed paraclinoid internal carotid artery aneurysms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374367PMC
http://dx.doi.org/10.5797/jnet.oa.2019-0046DOI Listing

Publication Analysis

Top Keywords

medially-directed paraclinoid
16
paraclinoid internal
16
internal carotid
16
carotid artery
16
simple reproducible
12
shaping method
12
artery aneurysms
12
pigtail-shaped mandrel
12
cases required
12
reproducible microcatheter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!