Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A composite optical bench made up of Carbon Fiber Reinforced Polymer (CFRP) skin and aluminum honeycomb has been developed for the Tunable Magnetograph instrument (TuMag) for the SUNRISE III mission within the NASA Long Duration Balloon Program. This optical bench has been designed to meet lightweight and low sensitivity to thermal gradient requirements, resulting in a low Coefficient of Thermal Expansion (CTE). In addition to the flight model, a breadboard model identical to the flight one has been manufactured, including embedded fiber Bragg temperature and strain sensors. The aim of this is to explore if the use of distributed fiber Bragg gratings (FBGs) can provide valuable information for strain and temperature mapping of an optical instrument on board a space mission during its operation as well as its on-ground testing. Furthermore, surface-mounted strain FBG sensors and thermocouples have been installed in the optical bench for intercomparison purposes. This paper presents the results obtained from a thermal vacuum test consisting of three thermal cycles with stabilization steps at 100 °C, 60 °C, 20 °C and -20 °C. Experimental results provide information about how FBG embedded temperature sensors can provide a proper and quick response to the temperature changes of the optical bench and that embedded FBG strain sensors are able to measure micro-deformation induced in a close-to-zero CTE optical bench.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384925 | PMC |
http://dx.doi.org/10.3390/s23146499 | DOI Listing |