Participants in trail running races must carry their equipment throughout the race. This additional load modifies running biomechanics. Novel running powermeters allow further analyses of key running metrics. This study aims to determine the acute effects of running with extra weights on running power generation and running kinematics at submaximal speed. Fifteen male amateur trail runners completed three treadmill running sessions with a weighted vest of 0-, 5-, or 10% of their body mass (BM), at 8, 10, 12, and 14 km·h. Mean power output (MPO), leg spring stiffness (LSS), ground contact time (GCT), flight time (FT), step frequency (SF), step length (SL), vertical oscillation (VO), and duty factor (DF) were estimated with the Stryd wearable system. The one-way ANOVA revealed higher GCT and MPO and lower DF, VO, and FT for the +10% BM compared to the two other conditions ( < 0.001) for the running speeds evaluated (ES: 0.2-7.0). After post-hoc testing, LSS resulted to be higher for +5% BM than for the +10% and +0% BM conditions (ES: 0.2 and 0.4). Running with lighter loads (i.e., +5% BM) takes the principle of specificity in trail running one step further, enhancing running power generation and LSS.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384182 | PMC |
http://dx.doi.org/10.3390/s23146411 | DOI Listing |
Multimed Man Cardiothorac Surg
January 2025
Respiratory Disease Center, Kyoto Katsura Hospital, Kyoto, Japan.
The plane running between two adjacent pulmonary segments consists of a very thin layer of connective tissue through which the pulmonary vein also runs. To perform an anatomically correct segmentectomy, this segmental plane needs to be divided. Before the operation, the locations of vessels and bronchi are confirmed by three-dimensional computed tomography.
View Article and Find Full Text PDFScand J Med Sci Sports
January 2025
Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
Measuring lower extremity impact acceleration is a common strategy to identify runners with increased injury risk. However, existing axial peak tibial acceleration (PTA) thresholds for determining high-impact runners typically rely on small samples or fixed running speeds. This study aimed to describe the distribution of axial PTA among runners at their preferred running speed, determine an appropriate adjustment for investigating impact magnitude at different speeds, and compare biomechanics between runners classified by impact magnitude.
View Article and Find Full Text PDFJ Biomech Eng
January 2025
Department of Mechanical Engineering, Vanderbilt University, 2201 West End Avenue, Nashville, TN, 37235.
Achilles tendon overuse injuries are common for long-distance runners. Ankle exos (exoskeletons and exosuits) are wearable devices that can reduce Achilles tendon loading and could potentially aid in the rehabilitation or prevention of these injuries by helping to mitigate and control tissue loading. However, most ankle exos are confined to controlled lab testing and are not practical to use in real-world running.
View Article and Find Full Text PDFPhys Sportsmed
January 2025
Faculty of Sport Sciences, University of Extremadura, Cáceres, Spain.
Objectives: This study aimed to compare the psychological demands and external workload experienced in the seven sessions leading up to injuries and the demands in the month preceding the injury week among professional Brazilian soccer players.
Methods: Initially, 33 players participated, but only 15 were included in the analysis due to the occurrence of twenty-three muscle-tendon injuries recorded according to International Olympic Committee (IOC) guidelines. The study assessed muscle-tendon injuries, rate of perceived exertion (RPE), and psychological variables (i.
Magn Reson Med
January 2025
Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!