Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study proposes a novel variable air pressure supply structure based on the electromagnetic effect. This structure can be implemented in various soft robots driven by air pressure, including pneumatic artificial muscles, pneumatic soft grippers, and other soft robots. The structure's main body comprises a hollow circular tube, a magnetic piston arranged in the tube, and an electromagnetic solenoid nested outside the tube. The electromagnetic solenoid is designed with special winding and power supply access modes, generating either an attractive force or a repulsive force on the magnetic piston. This solenoid conforms with the magnetic piston expectation in the tube by changing the polarity direction. The interior of the whole structure is a closed space. The gas is conveyed to the soft robot by the gas guide hoses at the two ends of the structure, and the expansion energy of the compressed gas is fully utilized. Then, the gas supply pressure is controlled to drive the robot. The mathematical model of the structure is established based on the analysis of the electromagnetic force and gas pressure on the piston. The simulation results show that the structure's inherent vibration characteristics under various parameters align with expectations. The real-time automatic optimization of the controller parameters is realized by optimizing the incremental proportional-integral-derivative (PID) controller based on a neural network. The simulation results show that the structure can meet the application requirements. The experimental results show that the proposed gas supply structure can provide a continuous pressure supply curve with any frequency in a specific amplitude range and has an excellent tracking effect on the sinusoidal-like pressure curve.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10385017 | PMC |
http://dx.doi.org/10.3390/s23146341 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!