A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Speckle Vibrometry for Instantaneous Heart Rate Monitoring. | LitMetric

Instantaneous heart rate (IHR) has been investigated for sleep applications, such as sleep apnea detection and sleep staging. To ensure the comfort of the patient during sleep, it is desirable for IHR to be measured in a contact-free fashion. In this work, we use speckle vibrometry (SV) to perform on-skin and on-textile IHR monitoring in a sleep setting. Minute motions on the laser-illuminated surface can be captured by a defocused camera, enabling the detection of cardiac motions even on textiles. We investigate supine, lateral, and prone sleeping positions. Based on Bland-Altman analysis between SV cardiac measurements and electrocardiogram (ECG), with respect to each position, we achieve the best limits of agreement with ECG values of [-8.65, 7.79] bpm, [-9.79, 9.25] bpm, and [-10.81, 10.23] bpm, respectively. The results indicate the potential of using speckle vibrometry as a contact-free monitoring method for instantaneous heart rate in a setting where the participant is allowed to rest in a spontaneous position while covered by textile layers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10386560PMC
http://dx.doi.org/10.3390/s23146312DOI Listing

Publication Analysis

Top Keywords

speckle vibrometry
12
instantaneous heart
12
heart rate
12
sleep
5
vibrometry instantaneous
4
rate monitoring
4
monitoring instantaneous
4
rate ihr
4
ihr investigated
4
investigated sleep
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!