A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Water Safety Plan, Monochloramine Disinfection and Extensive Environmental Sampling Effectively Control and Other Waterborne Pathogens in Nosocomial Settings: The Ten-Year Experience of an Italian Hospital. | LitMetric

contamination control is crucial in healthcare settings where patients suffer an increased risk of disease and fatal outcome. To ensure an effective management of this health hazard, the accurate application of a hospital-specific Water Safety Plan (WSP), the choice of a suitable water disinfection system and an extensive monitoring program are required. Here, the ten-year experience of an Italian hospital is reported: since its commissioning, Legionellosis risk management has been entrusted to a multi-disciplinary Working Group, applying the principles of the World Health Organization's WSP. The disinfection strategy to prevent and other waterborne pathogens relies on the treatment of domestic hot water with a system ensuring the in situ production and dosage of monochloramine. An average of 250 samples/year were collected and analyzed to allow an accurate assessment of the microbiological status of water network. With the aim of increasing the monitoring sensitivity, in addition to the standard culture method, an optimized MALDI-ToF MS-based strategy was applied, allowing the identification of species and other relevant opportunistic pathogens. Data collected so far confirmed the effectiveness of this multidisciplinary approach: the fraction of positive samples never overcame 1% on a yearly basis and Legionnaires' Disease cases never occurred.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384652PMC
http://dx.doi.org/10.3390/microorganisms11071794DOI Listing

Publication Analysis

Top Keywords

water safety
8
safety plan
8
waterborne pathogens
8
ten-year experience
8
experience italian
8
italian hospital
8
water
5
plan monochloramine
4
monochloramine disinfection
4
disinfection extensive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!