This paper presents an improved solution for the airflow energy harvester based on the push-pull diamagnetic levitation structure. A four-notch rotor is adopted to eliminate the offset of the floating rotor and substantially increase the energy conversion rate. The new rotor is a centrally symmetrical-shaped magnet, which ensures that it is not subjected to cyclically varying unbalanced radial forces, thus avoiding the rotor's offset. Considering the output voltage and power of several types of rotors, the four-notch rotor was found to be optimal. Furthermore, with the four-notch rotor, the overall average increase in axial magnetic spring stiffness is 9.666% and the average increase in maximum monostable levitation space is 1.67%, but the horizontal recovery force is reduced by 3.97%. The experimental results show that at an airflow rate of 3000 sccm, the peak voltage and rotation speed of the four-notch rotor are 2.709 V and 21,367 rpm, respectively, which are 40.80% and 5.99% higher compared to the three-notch rotor. The experimental results were consistent with the analytical simulation. Based on the improvement, the energy conversion factor of the airflow energy harvester increased to 0.127 mV/rpm, the output power increased to 138.47 mW and the energy conversion rate increased to 58.14%, while the trend of the levitation characteristics also matched the simulation results. In summary, the solution proposed in this paper significantly improves the performance of the airflow energy harvester.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383732 | PMC |
http://dx.doi.org/10.3390/mi14071374 | DOI Listing |
Water Res
December 2024
School of Energy and Environment, City University of Hong Kong, Hong Kong SAR, China; State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong SAR, China. Electronic address:
Airflow models are powerful tools for ventilation design to achieve odour and corrosion mitigation in sewer networks. Currently, there lacks a model able to efficiently predict in-sewer dynamic airflows, as all available dynamic models with an acceptable accuracy are computationally demanding. In this study, a swift dynamic airflow model based on an ordinary differential equation (ODE) is derived by simplifying the one-dimensional Navier Stokes Equations (NSE), supported by the observation that the NSE solutions always display negligible spatial variations in air velocity when applied to a sewer conduit.
View Article and Find Full Text PDFPLoS One
January 2025
College of Safety Science and Engineering, Liaoning Technical University, Fuxin, Liaoning, China.
To investigate the impact of the oxidation temperature and variations in airflow conditions on coal spontaneous combustion characteristics, pre-oxidized coal samples were prepared using a programmed temperature rise method. Synchronous thermal analysis experiments and Fourier transform infrared spectroscopy were conducted to explore changes in the thermal effects and functional group content of the coal samples, respectively. The results indicate that variations in pre-oxidation conditions primarily in fluence the activation temperature and maximum weight loss temperature of the coal samples, while exerting a lesser impact on the critical temperature and ignition point.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Electromechanical Engineering, University of Beira Interior, Rua Marquês d'Ávila e Bolama, 6201-001 Covilhã, Portugal.
This article presents the development of a resistive frost-detection sensor fabricated using Fused Filament Fabrication (FFF) with a conductive filament. This sensor was designed to enhance demand-defrost control in industrial refrigeration systems. Frost accumulation on evaporator surfaces blocks airflow and creates a thermal insulating barrier that reduces heat exchange efficiency, increasing energy consumption and operational costs.
View Article and Find Full Text PDFSci Total Environ
January 2025
College of Emergency Management and Safety Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China; Beijing Key Laboratory for Precise Mining of Intergrown Energy and Resources, China University of Mining and Technology (Beijing), Beijing 10083, China.
Slow oxidation of coal during storage and transportation poses significant risks, making it essential to identify hot spots and understand the heat generation and gas production patterns in coal stockpiles. This study leverages the advantages of adiabatic oxidation experiments, which account for time effects, to accurately describe the low-temperature oxidation process of coal through warming and gas production dimensions. Additionally, the warming and gas production patterns of three-dimensional coal stockpiles with varying stacking parameters were investigated.
View Article and Find Full Text PDFSensors (Basel)
November 2024
Faculty of Mechanical Engineering, Lublin University of Technology, 36, 20-618 Lublin, Poland.
This paper experimentally examines the influence of hybrid excitation on the performance of vibrational piezoelectric energy harvesting systems on a bluff body with a variable cross section along its generatrix. A combination of vibrational excitation from a shaker and airflow is considered the source from which energy is harvested. Varied excitation frequencies and airflow velocities across five different masses were considered, each defining the natural frequency of the system.