Background: The aim of this study was to assess the correlation between the overall rest-stress distance measured by transperineal ultrasound (TPUS) and Q-tip test angle in women with urodynamic stress incontinence (USI), and determine a cut-off value of rest-stress distance for predicting urethral hypermobility (UH).

Methods: Women with USI scheduled for mid-urethral sling surgery were retrospectively recruited. UH was defined as a Q-tip angle more than or equal to 30 degrees. Ultrasonic measurement of the overall rest-stress distance was defined as the linear distance of bladder-neck position change from resting status to maximal strain.

Results: Among the 132 enrolled women, the Pearson correlation coefficient between the overall rest-stress distance in TPUS and Q-tip test angle was 0.9104 (95% CI, 0.8758-0.9357, < 0.001). In receiver-operating-characteristic-curve analysis, a rest-stress distance of more than 13.3 mm was an optimal cut-off value to predict UH (sensitivity = 76.47%, specificity = 93.3%; area = 0.937, 95% confidence interval: 0.881-0.972).

Conclusions: The overall rest-stress distance in TPUS correlated well with the Q-tip test angle, indicating that it can be an alternative method for the assessment of USI. A rest-stress distance of more than 13.3 mm was an optimal cut-off value to predict UH in women with USI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10381566PMC
http://dx.doi.org/10.3390/jcm12144863DOI Listing

Publication Analysis

Top Keywords

rest-stress distance
28
q-tip test
16
test angle
12
urethral hypermobility
8
distance
8
tpus q-tip
8
women usi
8
distance tpus
8
distance 133
8
133 optimal
8

Similar Publications

Background: The aim of this study was to assess the correlation between the overall rest-stress distance measured by transperineal ultrasound (TPUS) and Q-tip test angle in women with urodynamic stress incontinence (USI), and determine a cut-off value of rest-stress distance for predicting urethral hypermobility (UH).

Methods: Women with USI scheduled for mid-urethral sling surgery were retrospectively recruited. UH was defined as a Q-tip angle more than or equal to 30 degrees.

View Article and Find Full Text PDF

Background: The vascular endothelium is a novel target for the detection, management, and prevention of doxorubicin (DOX)-induced cardiotoxicity.

Objectives: The study aimed to: 1) develop a methodology by computed tomography angiography (CTA) to evaluate stress-induced changes in epicardial coronary diameter; and 2) apply this to a chronic canine model of DOX-induced cardiotoxicity to assess vascular toxicity.

Methods: To develop and validate quantitative methods, sequential retrospectively gated coronary CTAs were performed in 16 canines.

View Article and Find Full Text PDF

Background: Patient motion can lead to misalignment of left ventricular (LV) volumes-of-interest (VOIs) and subsequently inaccurate quantification of myocardial blood flow (MBF) and flow reserve (MFR) from dynamic PET myocardial perfusion images. We aimed to develop an image-based 3D-automated motion-correction algorithm that corrects the full dynamic sequence for translational motion, especially in the early blood phase frames (~ first minute) where the injected tracer activity is transitioning from the blood pool to the myocardium and where conventional image registration algorithms have had limited success.

Methods: We studied 225 consecutive patients who underwent dynamic rest/stress rubidium-82 chloride (Rb) PET imaging.

View Article and Find Full Text PDF

Purpose: Perfusion analysis from first-pass contrast enhancement kinetics requires modeling tissue contrast exchange. This study presents a new approach for numerical implementation of the tissue homogeneity model, incorporating flexible distance steps along the capillary (NTHf).

Methods: The proposed NTHf model considers contrast exchange in fluid packets flowing along the capillary, incorporating flexible distance steps, thus allowing more efficient and stable calculations of the transit of tracer through the tissue.

View Article and Find Full Text PDF

Purpose: We prospectively determined whether preimplant myocardial perfusion imaging (MPI) predicts outcome with biventricular pacing (BiVP).

Methods: Single-photon emission computed tomography (SPECT) MPI, left ventricular (LV) volumes, ejection fraction (EF), 6-min hall walk (6MW) were assessed at baseline and at 4 months in 19 patients with ischemic cardiomyopathy undergoing BiVP. Clinical and hemodynamic responses were correlated with MPI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!