This study aims to systematise subfoveal choroidal thickness (SFCT) measured using optical coherence tomography (OCT) in patients with different severities of thyroid eye disease (TED) compared with healthy subjects. The PubMed, Web of Science and Scopus databases were searched for the following terms: ((Graves' ophthalmopathy) OR (thyroid eye disease) OR (Graves' orbitopathy) OR (thyroid-associated orbitopathy)) AND (choroidal thickness) AND ((optical coherence tomography) OR (OCT)). The pool of papers was narrowed down to articles published until 31 January 2023 (26, 26 and 96 papers, respectively). Twenty-five (25) articles were taken into consideration, which were original papers and included the choroidal thickness measurements among TED patients in their results. Finally, eight papers were included in the comparative analysis of the SFCT parameter in TED patients and a group of healthy controls, and seven papers in the comparative analysis of the same parameter between active and inactive TED patients. The mean value of the difference between the TED group and the healthy group was 38.79 μm, with a confidence interval (CI) from 0.09 to 77.49 μm ( = 0.0495). The mean difference between the active TED group and inactive TED group was 38.02 μm, with a CI from 8.62 to 67.42 μm ( = 0.0113). All the results were statistically significant.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10380986PMC
http://dx.doi.org/10.3390/jcm12144720DOI Listing

Publication Analysis

Top Keywords

choroidal thickness
16
thyroid eye
12
eye disease
12
ted patients
12
ted group
12
subfoveal choroidal
8
optical coherence
8
coherence tomography
8
tomography oct
8
papers included
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!