Submission of a non-biological parent together with a proband for genetic diagnosis would cause a misattributed parentage (MP), possibly leading to misinterpretation of the pathogenicity of genomic variants. Therefore, a rapid and cost-effective paternity/maternity test is warranted before genetic testing. Although low-pass genome sequencing (GS) has been widely used for the clinical diagnosis of germline structural variants, it is limited in paternity/maternity tests due to the inadequate read coverage for genotyping. Herein, we developed rapid paternity/maternity testing based on low-pass GS with trio-based and duo-based analytical modes provided. The optimal read-depth was determined as 1-fold per case regardless of sequencing read lengths, modes, and library construction methods by using 10 trios with confirmed genetic relationships. In addition, low-pass GS with different library construction methods and 1-fold read-depths were performed for 120 prenatal trios prospectively collected, and 1 trio was identified as non-maternity, providing a rate of MP of 0.83% (1/120). All results were further confirmed via quantitative florescent PCR. Overall, we developed a rapid, cost-effective, and sequencing platform-neutral paternity/maternity test based on low-pass GS and demonstrated the feasibility of its clinical use in confirming the parentage for genetic diagnosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10379141 | PMC |
http://dx.doi.org/10.3390/genes14071357 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!