Microchip capillary electrophoresis in mixed hydro-organic solvent combined with laser-induced fluorescence detection was developed for the separation and detection of physcion and rhein in rhubarb. In contrast to the conventional capillary electrophoresis method, ammonium acetate-dimethyl sulfoxide was used as the basic buffer system in this method. The effects of background buffer, buffer apparent pH*, buffer concentration, water ratio, sample preparation method, and separation voltage on separation and detection were investigated. Optimized separation and detection conditions were obtained: the buffer consisted of 20 mmol/L of ammonium acetate in hydro-organic solvent composed dimethyl sulfoxide, formamide, and water mixed at 60/20/20 (v/v/v) ratio. The separation voltage was 1.9 kV. Under these conditions, the physcion, rhein, and other components of rhubarb can be completely separated within 150 s. Under the methodological verification, good linearity (R ≥ 0.9995) for physcion and rhein, and low limits of detection (0.085 μg·mL and 0.077 μg·mL , respectively), satisfactory peak area precisions, migration time precisions (1.74%-3.09%), and accuracy (recovery rate 97.8% and 101.4%) were achieved. It is shown that the proposed method is simple, efficient, fast, sensitive, simple instrument, consumes few samples, has low operating cost, and is linear.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.202300192DOI Listing

Publication Analysis

Top Keywords

capillary electrophoresis
12
hydro-organic solvent
12
separation detection
12
physcion rhein
12
microchip capillary
8
electrophoresis mixed
8
mixed hydro-organic
8
solvent combined
8
combined laser-induced
8
laser-induced fluorescence
8

Similar Publications

Ribosomes, discovered in 1955 by George Palade, were initially described as small cytoplasmic particles preferentially associated with the endoplasmic reticulum (ER). Over the years, extensive research has focused on both the structure and function of ribosomes. However, a fundamental question - how many ribosomes are present within whole cells - has remained largely unaddressed.

View Article and Find Full Text PDF

Personal care products (PCPs), such as sunscreens, are usually found in various aquatic ecosystems at low concentrations (ng l to µg l). However, there is limited information regarding their effects on marine bivalves. Therefore, the aim of this study was to evaluate the sublethal effects of environmental concentrations (1 and 100 µg l) of benzophenone-3 (BP-3) in Crassostrea gigas oysters after 1 and 7 days of exposure.

View Article and Find Full Text PDF

Investigation and elimination of noncovalent artificial aggregates during non-reduced capillary electrophoresis-sodium dodecyl sulfate analysis of a multi-specific antibody.

J Pharm Biomed Anal

January 2025

State Key Laboratory of Neurology and Oncology Drug Development, Nanjing, China; Simcere Zaiming Pharmaceutical Co, Ltd., Nanjing, China. Electronic address:

Capillary electrophoresis-sodium dodecyl sulfate (CE-SDS) is widely used in the biopharmaceutical industry for monitoring purity and analyzing impurities. The accuracy of the method may be compromised by artificial species resulting from sample preparation or electrophoresis separation due to suboptimal conditions. During non-reduced CE-SDS analysis of a multispecific antibody (msAb), named as multispecific antibody C (msAb-C), a cluster of unexpected peaks was observed after the main peak.

View Article and Find Full Text PDF

Background: Hemoglobin G-Siriraj is a rare hemoglobin variant caused by a β-globin gene mutation (HBB: c.22G>A). The focus of this paper is aimed mainly at the chromatographic and electrophoretic properties of hemoglobin G-Siriraj for a presumptive identification.

View Article and Find Full Text PDF

Background: Glycosylated hemoglobin (HbA1c) is a stable compound in human blood that covalently binds the N-terminal valine residue of the β-chain in hemoglobin A to the free aldehyde group of glucose. It can reflect the average blood glucose level of patients in the past 2 - 3 months. Therefore, the accuracy of HbA1c detection results is of great significance for the diagnosis and differential diagnosis of diabetes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!