Background: There is no consensus regarding the acceptable level of medical radiation exposure in patients with early-onset scoliosis. This study aimed to quantify radiation exposure in these patients and investigate factors associated with high exposure.

Methods: Patients with early-onset scoliosis who received care for their spine deformity and other comorbidities in our institution were retrospectively reviewed. Cumulative radiation exposure and total number of imaging studies were recorded. Patients with ≥30 mSv exposure were classified as high exposure and analyzed to clarify factors associated with high exposure.

Results: Thirty-five patients were included for analysis. The etiology of scoliosis was idiopathic in 8 patients, congenital in 7, syndromic in 8, and neuromuscular in 12. Fifteen patients underwent 19 spinal surgeries. The types of operation performed were definitive fusion (n = 12), vertebrectomy for hemivertebra (n = 2), growing rod (n = 1), lengthening (n = 3), and revision/partial implant removal (n = 1). The mean cumulative radiation dose was 22.3 mSv (range, 2.5-94.5 mSv). Spine radiography and computed tomography combined accounted for 15.0 mSv (range, 2.4-52.5 mSv, 67.3% of the mean cumulative dose). The mean radiation dose was significantly higher in patients who underwent spinal surgery than in those who did not (31.2 mSv vs. 15.6 mSv). The high-exposure group comprised 10 patients (1 idiopathic, 1 congenital, 5 syndromic, and 3 neuromuscular scoliosis) and 8 underwent 11 spinal operations. Among 8 patients who underwent spinal surgery, the cumulative radiation dose for spine was ≥30 mSv and spine computed tomography was performed an average of 4.0 times.

Conclusions: Nearly one-third of patients with early-onset scoliosis and half of patients who underwent spinal surgery had >30 mSv radiation exposure due to multiple computed tomography. Medical radiation exposure and associated cancer risk should be considered when treating these patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jos.2023.07.008DOI Listing

Publication Analysis

Top Keywords

radiation exposure
24
underwent spinal
20
patients underwent
16
patients
14
patients early-onset
12
early-onset scoliosis
12
cumulative radiation
12
radiation dose
12
computed tomography
12
spinal surgery
12

Similar Publications

Evaluation of a Deep Learning Denoising Algorithm for Dose Reduction in Whole-Body Photon-Counting CT Imaging: A Cadaveric Study.

Acad Radiol

January 2025

Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).

Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.

Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).

View Article and Find Full Text PDF

Inverse dose protraction effects of high-LET radiation: evidence and significance.

Mutat Res Rev Mutat Res

January 2025

Radiation Epidemiology Branch, National Cancer Institute, MD 20892-9778, USA; Faculty of Health, Science and Technology, Oxford Brookes University, Headington Campus, OX3 0BP, UK.

Biological effects of ionizing radiation vary with radiation quality, which is often expressed as the amount of energy deposited per unit length, i.e., linear energy transfer (LET).

View Article and Find Full Text PDF

Characterization of Cutaneous Radiation Syndrome in a Mouse Model Using [18F]F- Fluorodeoxyglucose Positron Emission Tomography.

Health Phys

January 2025

Nuclear Medicine and Molecular Imaging Sciences Program, Department of Clinical & Diagnostic Sciences, School of Health Professions, University of Alabama at Birmingham, Birmingham, AL.

Ionizing radiation on the skin has the potential to cause various sequelae affecting quality of life and even leading to death due to multi-system failure. The development of radiation dermatitis is attributed to oxidative damage to the skin's basal layer and alterations in immune response, leading to inflammation. Past studies have shown that [18F]F-2-fluoro-2-deoxyglucose positron emission tomography-computed tomography ([18F]F-FDG PET/CT) can be used effectively for the detection of inflammatory activity, especially in conditions like hidradenitis suppurativa, psoriasis, and early atherosclerosis.

View Article and Find Full Text PDF

Metal-free molecular perovskites have shown great potential for X-ray detection due to their tunable chemical structures, low toxicity, and excellent photophysical properties. However, their limited X-ray absorption and environmental instability restrict their practical application. In this study, cesium-based molecular perovskites (MDABCO-CsX, X = Cl, Br, I) are developed by introducing Cs at the B-site to enhance X-ray absorption while retaining low toxicity.

View Article and Find Full Text PDF

In 2023, a breast cancer risk assessment and a subsequent positive test for the BRCA-2 genetic mutation brought me to the uncomfortable intersection of a longstanding career as an advocate for high-quality medical evidence to support shared patient-provider decision making and a new role as a high-risk patient. My search for studies of available risk-management options revealed that the most commonly recommended approach for women with a ⩾20% lifetime breast cancer risk, intensive screening including annual mammography and/or magnetic resonance imaging beginning at age 25-40 years, was supported only by cancer-detection statistics, with almost no evidence on patient-centered outcomes-mortality, physical and psychological morbidity, or quality of life-compared with standard screening or a surgical alternative, bilateral risk-reducing mastectomy. In this commentary, I explore parallels between the use of the intensive screening protocol and another longstanding women's health recommendation based on limited evidence, the use of hormone therapy (HT) for postmenopausal chronic disease prevention, which was sharply curtailed after the publication of the groundbreaking Women's Health Initiative trial in 2002.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!