A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of pediatric shoulder range of motion and loading response to evaluate the biofidelity of the Large Omni-directional Child (LODC) anthropomorphic test device (ATD) shoulder design. | LitMetric

The shoulder girdle complex, through engagement with the seat belt, influences motor vehicle occupant upper body movement during frontal impacts, affecting the movement of the head and spine. The recently developed Large Omni-directional Child (LODC) anthropomorphic test device (ATD) was designed with flexible shoulder girdle structures that capture the unique kinematics in pediatric occupants. However, the LODC shoulder has not been evaluated for biofidelity due to the lack of biomechanical data available on pediatric shoulder responses. This study evaluated quasi-static pediatric shoulder girdle complex responses through non-invasive displacement measurements. These data were obtained to evaluate, and, if necessary, improve the biofidelity of the LODC ATD. Shoulder range of motion and anthropometric measurements were obtained from 25 pediatric volunteers, ages 8-12 years old. Loads were applied bilaterally exclusively to the shoulder complexes in increments of 25 N up to 150 N per shoulder at 90 and 135 degrees of shoulder flexion. Still photos were used to determine shoulder displacement in the sagittal plane from images captured prior to and following the load applications. Data analysis consisted of motion tracking to evaluate the absolute and relative displacement of the right acromion and T1. The displacements for each volunteer were normalized based on the volunteer's shoulder width compared to the shoulder width of the LODC ATD. For the 90° load, the acromion moved relative to T1 an average of 28.1 mm forward and 3.1 mm downward at maximum displacement. For the 135° load, the acromion moved relative to T1 an average of 15.5 mm forward and 42.7 mm upward at maximum displacement. Similar displacements at higher loads indicated that the volunteers achieved their maximum range of motion. The results of this study will be compared to the LODC ATD, assessing the biofidelity of the shoulder complex.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aap.2023.107220DOI Listing

Publication Analysis

Top Keywords

shoulder
15
pediatric shoulder
12
range motion
12
shoulder girdle
12
lodc atd
12
shoulder range
8
large omni-directional
8
omni-directional child
8
child lodc
8
lodc anthropomorphic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!