Covered stent correction of a superior sinus venosus atrial septal defect is increasingly performed as an alternative to surgical repair. While sinus node dysfunction requiring pacemaker implantation may be required after surgical repair, this has not been previously reported after covered stent implantation. We reviewed the experience in two interventional centers. Balloon inflation in the superior vena cava was used to confirm the anomalous pulmonary vein drainage would be unobstructed after stent implantation. During balloon testing in 62 consecutive patients, we assessed gradients across the pulmonary vein to left atrium while monitoring the rhythm. We observed the outcomes after covered stent correction in 51 patients. In a single patient, significant bradycardia and pauses developed on repeat balloon testing and the procedure was abandoned without stent implantation. In another patient, there was no sign of sinus node dysfunction during balloon testing but several hours after stent implantation, the patient became symptomatic from sinus bradycardia and pauses and had a pacemaker implanted 3 days later. Over a year later there are some signs of improvement in sinus node function. While sinus node dysfunction has not been described previously during balloon testing or after stent implantation, this report demonstrates for the first time that it may occur. Larger registries are therefore required to monitor for this uncommon complication.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.30790 | DOI Listing |
Cell Rep
December 2024
Precision Cardiology Laboratory, The Broad Institute, Cambridge, MA 02142, USA; Cardiovascular Research Center, Massachusetts General Hospital, Boston, MA 02114, USA; Cardiology Division, Massachusetts General Hospital, Boston, MA 02114, USA. Electronic address:
We sought to characterize cellular composition across the cardiovascular system of the healthy Wistar rat, an important model in preclinical cardiovascular research. We performed single-nucleus RNA sequencing (snRNA-seq) in 78 samples in 10 distinct regions, including the four chambers of the heart, ventricular septum, sinoatrial node, atrioventricular node, aorta, pulmonary artery, and pulmonary veins, which produced 505,835 nuclei. We identified 26 distinct cell types and additional subtypes, with different cellular composition across cardiac regions and tissue-specific transcription for each cell type.
View Article and Find Full Text PDFNeurol Sci
December 2024
Division of Cardiology, Cardio-Thoracic Department, University Hospital of Verona, Verona, Italy.
Background: Implantable loop recorders (ILRs) have been shown to significantly improve the detection of atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS). The incidence and characterization of bradyarrhythmias in this subset of patients is still unknown.
Methods: All consecutive patients who received ILRs, after an ESUS, between March 2015 and December 2022 in our Center were retrospectively enrolled and analyzed.
Cardiol Rev
November 2024
Department of Cardiovascular Medicine, Cardiovascular Analytics Group, Islamabad, Pakistan.
A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
December 2024
Section of Cardiac Electrophysiology, Division of Cardiovascular Medicine, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia.
Background: Patients undergoing first-time atrial fibrillation (AF) ablation can benefit from targeting non-pulmonary vein (PV) triggers. Preprocedural identification of high-risk individuals can guide planning of ablation strategy. This study aimed to create a preprocedural screening tool to identify patients at risk of non-PV triggers during first-time AF ablation.
View Article and Find Full Text PDFFront Med (Lausanne)
December 2024
Division of Cardiovascular Sciences, School of Medical Sciences, University of Manchester, Manchester, United Kingdom.
Background: The sinoatrial node (SN) generates the heart rate (HR). Its spontaneous activity is regulated by a complex interplay between the modulation by the autonomic nervous system (ANS) and intrinsic factors including ion channels in SN cells. However, the systemic and intrinsic regulatory mechanisms are still poorly understood.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!