A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characterization of the substernal space with computed tomography imaging in patients with and without median sternotomy: Assessing a novel implant location for extravascular defibrillation lead placement. | LitMetric

AI Article Synopsis

  • This study investigates the use of computed tomography (CT) to analyze the space between the sternum and heart in patients with and without previous sternotomy, aiming to explore the possibility of implanting ICD leads in those who have had chest surgeries.
  • 100 patients were assessed, with half having had midline sternotomy, measuring the distance from the sternum to the heart across different regions.
  • Results revealed a narrower sternum-to-heart distance in those with sternotomy, suggesting that despite the reduced space, there is potential for safely implanting ICD leads in these patients.

Article Abstract

Background: Implantable cardioverter-defibrillators (ICDs) provide clinically significant therapy for the prevention of sudden cardiac death. This study aimed to characterize the substernal space using computed tomography (CT) in patients with and without prior midline sternotomy to investigate the feasibility of substernal ICD lead implantation in post-sternotomy patients.

Methods: High-quality electrocardiogram-gated CT images from 100 patients (71% male, average body mass index 23.5 ± 2.9) were retrospectively collected, including 50 patients with prior midline sternotomy (S-group) and 50 patients with no prior sternotomy (NS-group). Distances were measured from the retrosternal surface to the epicardial surface of the heart and segmented into four regions from the xiphoid tip and superiorly along the sternum.

Results: Results generally showed a measurable but narrower average sternum-to-heart distance in the prior sternotomy group compared to the non-sternotomy group in all four regions (p < .05). In the S-group, the sternum-to-heart distances across all regions ranged from 0 to 32.0 mm, while in the NS-group, the distances ranged from 0 to 39.9 mm.

Conclusion: Small but measurable separations between the heart and sternum were observed in patients with prior sternotomy, particularly near the xiphoid region, indicating the potential viability of extravascular substernal ICD lead implantation in post-sternotomy patients.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.14797DOI Listing

Publication Analysis

Top Keywords

patients prior
12
substernal space
8
space computed
8
computed tomography
8
prior midline
8
midline sternotomy
8
prior sternotomy
8
patients
5
sternotomy
5
characterization substernal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!