Reliable detection of specific antibodies against pathogens by lateral flow immunoassay (LFIA) greatly depends on the composition of the detectable complex and the order of its assembly. We compared three LFIA formats for revealing anti-SARS-CoV-2 antibodies in sera with the following detected complexes in the analytical zone of the strip: antigen-antibodies-labeled immunoglobulin-binding protein (Scheme A); antigen-antibodies-labeled antigen (Scheme B); and immunoglobulin-binding protein-antibodies-labeled antigen (Scheme C). The lowest detection limit was observed for Scheme C, and was equal to 10 ng/mL of specific humanized monoclonal antibodies. When working with pooled positive sera, Scheme C had a detection limit 15 times lower than Scheme B and 255 times lower than Scheme A. Due to the high sensitivity of Scheme C, its application for the panel of human sera (n = 22) demonstrated 100% diagnostic specificity and sensitivity. These consistent results be useful for designing the format of LFIA serodiagnosis for other diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10376990PMC
http://dx.doi.org/10.3390/bios13070750DOI Listing

Publication Analysis

Top Keywords

lateral flow
8
flow immunoassay
8
scheme
8
antigen scheme
8
detection limit
8
times lower
8
lower scheme
8
comparison three
4
three lateral
4
immunoassay formats
4

Similar Publications

Stacking paper sheets into multi-purpose quick response sensing code with built-in nitrocellulose-membrane-free lateral flow assay for detecting tetracycline in food samples.

Food Chem

January 2025

State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510640, China; Guangdong Provincial Key Laboratory of Plant Resources Biorefinery, Guangzhou 510006, China. Electronic address:

Lateral flow assays (LFAs) have found extensive applications in food safety and quality monitoring. Now, smartphone technology is redefining how tests are conducted at the point of use. At the same time, quick response (QR) codes enhance digital connectivity for information transmission, data collection, and response linkage.

View Article and Find Full Text PDF

Nanoporous graphene (NPG), laterally bonded carbon nanoribbons, is a promising platform for controlling coherent electron propagation in the nanoscale. However, for its successful device integration NPG should ideally be on a substrate that preserves or enhances its anisotropic transport properties. Here, using an atomistic tight-binding model combined with nonequilibrium Green's functions, we study NPG on graphene and show that their electronic coupling is modulated as a function of the interlayer twist angle.

View Article and Find Full Text PDF

Despite being a high-resolution separation technique, deterministic lateral displacement (DLD) technology is facing multiple challenges with regard to design, manufacture, and operation of pertinent devices. This work specifically aims at alleviating difficulties associated with design and manufacture of DLD chips. The process of design and production of computer-aided design (CAD) mask layout files that are typically required for computational modeling analysis, optimization, as well as for manufacturing DLD-based micro/nanofluidic chips is complex, time-consuming, and often necessitates a high level of expertise in the field.

View Article and Find Full Text PDF

To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.

View Article and Find Full Text PDF

Background: The UK's National Health Service Test and Trace (NHSTT) program aimed to provide the most effective and accessible SARS-CoV-2 testing approach possible. Early user feedback indicated that there were accessibility issues associated with throat swabbing. We report the results of service evaluations performed by NHSTT to assess the effectiveness and user acceptance of swabbing approaches, as well as qualitative findings of user experiences from research reports, surveys, and incident reports.

View Article and Find Full Text PDF