AI Article Synopsis

  • * Out of 66 patients treated, 82% achieved either complete obliteration or had a residual neck, while 18% had residual aneurysms; the position of the microcatheter significantly influenced these results.
  • * The findings indicate that for superior position aneurysms, placing the microcatheter at the lesser curvature may lead to better initial occlusion outcomes compared to the greater curvature position.

Article Abstract

Objective: Endovascular treatment of anterior communicating artery aneurysms is difficult due to their complex anatomical structure. We retrospectively analyzed the relationships among the anatomical features, initial microcatheter positions, and initial occlusion outcomes.

Methods: In all, 66 cases were treated at our hospital. We investigated the relationships among the anatomical features of the aneurysm and A1 segment of the anterior cerebral artery (ACA), treatment procedures, and initial occlusion outcomes. We divided the initial microcatheter positions into greater and lesser curvatures based on the curvature from A1 to the aneurysm, and evaluated the outcomes.

Results: In total, 54 out of 66 patients (82%) achieved complete obliteration (CO) or had residual neck (RN) aneurysms, and 12 had residual aneurysms (RAs: 18%). Neck diameters and superior position aneurysms were correlated with initial occlusion outcomes in the multivariate analysis. The relationship between initial occlusion outcomes and initial microcatheter positions in superior position aneurysms (37 patients) was then examined. Eleven out of 26 patients (42.3%) had residual aneurysms at the greater curvature microcatheter position, whereas no residual aneurysms were detected at the lesser curvature microcatheter position. The A1 angle was not correlated with the outcomes.

Conclusion: Wide-necked aneurysms and superior position aneurysms were identified as factors leading to incomplete occlusion in the endovascular treatment of anterior communicating artery aneurysms. The microcatheter position at the greater curvature in superior position aneurysms was a factor for incomplete occlusion. This suggests that guiding the microcatheter to the lesser curvature position of A1 is important in the treatment of superior position aneurysms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370672PMC
http://dx.doi.org/10.5797/jnet.oa.2020-0017DOI Listing

Publication Analysis

Top Keywords

superior position
20
position aneurysms
20
initial occlusion
16
aneurysms
13
relationships anatomical
12
endovascular treatment
12
treatment anterior
12
anterior communicating
12
communicating artery
12
artery aneurysms
12

Similar Publications

Background And Objectives: Accurate intraoperative assessment of coronal alignment is critical to achieving favorable clinical outcomes in adult spinal deformity surgery. However, surgical positioning creates challenges in predicting standing coronal alignment. Gravity-based plumblines require an upright posture and are not possible intraoperatively.

View Article and Find Full Text PDF

The growth and integration of position-controlled, morphology-programmable silicon nanowires (SiNWs), directly upon low-cost polymer substrates instead of postgrowth transferring, is attractive for developing advanced flexible sensors and logics. In this work, a low temperature growth of SiNWs at only 200 °C has been demonstrated, for the first time, upon flexible polyimide (PI) films, via a planar solid-liquid-solid (IPSLS) growth mechanism. The SiNWs with diameter of ∼146 nm can be grown into precise locations on PI as orderly array and with preferred elastic geometry.

View Article and Find Full Text PDF

AI integration into wavelength-based SPR biosensing: Advancements in spectroscopic analysis and detection.

Anal Chim Acta

March 2025

Artificial Intelligence Research Center, Chang Gung University, Taoyuan, 333323, Taiwan; Department of Artificial Intelligence, College of Intelligent Computing, Chang Gung University, Taoyuan, 333323, Taiwan. Electronic address:

Background: In recent years, employing deep learning methods in the biosensing area has significantly reduced data analysis time and enhanced data interpretation and prediction accuracy. In some SPR fields, research teams have further enhanced detection capabilities using deep learning techniques. However, the application of deep learning to spectroscopic surface plasmon resonance (SPR) biosensors has not been reported.

View Article and Find Full Text PDF

Agreement between Color, Fluorescein Angiography, and SD-OCT in the Detection of Macular Fibrosis in Neovascular AMD.

Am J Ophthalmol

January 2025

Centre for Public Health, Faculty of Medicine and Health Sciences, Queen's University Belfast, Belfast, Northern Ireland, United Kingdom. Electronic address:

Purpose: Color imaging is the accepted reference standard for detection of macular fibrosis in neovascular age-macular degeneration. Other imaging modalities of fluorescein angiography (FA) and spectral domain optical coherence tomography (SD-OCT) are also used but no formal agreement studies exist. We evaluated the agreement between fibrosis on colour, FA and SD-OCT-detected hyperreflective material (HRM) and their clinical relevance.

View Article and Find Full Text PDF

Association between ACE (I/D) polymorphism and physical performance in Brazilian handballers.

Int J Sports Med

January 2025

Department of Biophysics and Physiology, Nucleus of Study in Physiology Applied to Performance and Health (NEFADS), Federal University of Piaui, Teresina, Brazil.

This study investigated the association between the ACE (I/D) polymorphism and strength phenotypes in Brazilian male handball players, considering their playing position. A total of 105 male junior handball players and 92 controls were evaluated. The ACE I/D polymorphism was genotyped by conventional PCR followed by electrophoresis in agarose gel.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!