A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Continuous enrichment and trace analysis of tetracyclines in bovine milk using dual-functionalized aqueous biphasic system combined with high-performance liquid chromatography. | LitMetric

Continuous enrichment and trace analysis of tetracyclines in bovine milk using dual-functionalized aqueous biphasic system combined with high-performance liquid chromatography.

J Dairy Sci

Key Laboratory of Coarse Cereal Processing, Ministry of Agriculture and Rural Affairs, Sichuan Engineering & Technology Research Center of Coarse Cereal Industralization, School of Food and Biological Engineering, Chengdu University, Chengdu 610106, People's Republic of China.

Published: September 2023

Two PPG based temperature-sensitive magnetic ionic liquid were synthesized and characterized. The temperature-sensitive magnetic ionic liquid aqueous biphasic system combined with HPLC was applied for the continuous enrichment and trace analysis of tetracycline antibiotics (TC) in bovine milk for the first time. High enrichment factors were achieved and the detection was highly sensitive. The trace analysis of TC was rapid, free of organic solvent, recyclable and magnetically assisted for phase separation. Under optimum conditions, wide linear ranges of 0.25-300 ng/mL for all TC, high enrichment factors of 217.7-231.4, good precisions with relative standard deviation in the range of 0.74-3.97%, very low limits of detection of 0.031-0.067 ng/mL, limits of quantification of 0.103-0.223 ng/mL, and good recoveries of 94.28-99.76% were acquired for the proposed analytical method. Real milk analysis was satisfactory. This developed analytical method is showing great potential for trace analysis of targeted analytes in foods and drinks.

Download full-text PDF

Source
http://dx.doi.org/10.3168/jds.2022-23034DOI Listing

Publication Analysis

Top Keywords

trace analysis
16
continuous enrichment
8
enrichment trace
8
bovine milk
8
aqueous biphasic
8
biphasic system
8
system combined
8
temperature-sensitive magnetic
8
magnetic ionic
8
ionic liquid
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!