A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Smartphone-based pH responsive 3-channel colorimetric biosensor for non-enzymatic multi-antibiotic residues. | LitMetric

Smartphone-based pH responsive 3-channel colorimetric biosensor for non-enzymatic multi-antibiotic residues.

Food Chem

Sanya Institute of Nanjing Agricultural University, MOE Joint International Research Laboratory of Animal Health and Food Safety, Key Laboratory of Animal Physiology & Biochemistry, College of Veterinary Medicine, Nanjing Agricultural University, Nanjing 210095, China. Electronic address:

Published: December 2023

Antibiotic residues in animal-derived food pose a risk to food safety and human health. Here, a smartphone-based pH-responsive 3-channel colorimetric biosensor is constructed for rapid detection of non-enzymatic multi-antibiotic residues in milk. In this system, a magnetic separation and enrichment approach is designed to specifically capture different antibiotic residues in complex environment. Indicators loaded on polydopamine-silver nanoparticles with excellently pH responsive visualization properties are utilized to ensure the high sensitivity of detection system. Moreover, smartphones are introduced to fulfill the demand for portable and on-site inspection of practical applications. It achieves simultaneous detection of oxytetracycline, kanamycin and streptomycin in the linear range of 1-10 pg/mL with detection limits of 0.085, 0.168, and 0.307 pg/mL, respectively. The practicality of the reported multi-antibiotic residues detection system is successfully demonstrated and evaluated challenging milk samples. Therefore, this system demonstrates the wide applications in multi-antibiotic residue analysis and food safety guarantee.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2023.136953DOI Listing

Publication Analysis

Top Keywords

multi-antibiotic residues
12
3-channel colorimetric
8
colorimetric biosensor
8
non-enzymatic multi-antibiotic
8
antibiotic residues
8
food safety
8
detection system
8
residues
5
detection
5
smartphone-based responsive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!