The 30-50% non-response rate to cardiac resynchronization therapy (CRT) calls for improved patient selection and optimized pacing lead placement. The study aimed to develop a novel technique using patient-specific cardiac models and machine learning (ML) to predict an optimal left ventricular (LV) pacing site (ML-PS) that maximizes the likelihood of LV ejection fraction (LVEF) improvement in a given CRT candidate. To validate the approach, we evaluated whether the distance D between the clinical LV pacing site (ref-PS) and ML-PS is associated with improved response rate and magnitude. We reviewed retrospective data for 57 CRT recipients. A positive response was defined as a more than 10% LVEF improvement. Personalized models of ventricular activation and ECG were created from MRI and CT images. The characteristics of ventricular activation during intrinsic rhythm and biventricular (BiV) pacing with ref-PS were derived from the models and used in combination with clinical data to train supervised ML classifiers. The best logistic regression model classified CRT responders with a high accuracy of 0.77 (ROC AUC = 0.84). The LR classifier, model simulations and Bayesian optimization with Gaussian process regression were combined to identify an optimal ML-PS that maximizes the ML-score of CRT response over the LV surface in each patient. The optimal ML-PS improved the ML-score by 17 ± 14% over the ref-PS. Twenty percent of the non-responders were reclassified as positive at ML-PS. Selection of positive patients with a max ML-score >0.5 demonstrated an improved clinical response rate. The distance D was shorter in the responders. The max ML-score and D were found to be strong predictors of CRT response (ROC AUC = 0.85). In the group with max ML-score > 0.5 and D< 30 mm, the response rate was 83% compared to 14% in the rest of the cohort. LVEF improvement in this group was higher than in the other patients (16 ± 8% vs. 7 ± 8%). A new technique combining clinical data, personalized heart modelling and supervised ML demonstrates the potential for use in clinical practice to assist in optimizing patient selection and predicting optimal LV pacing lead position in HF candidates for CRT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10367108PMC
http://dx.doi.org/10.3389/fphys.2023.1162520DOI Listing

Publication Analysis

Top Keywords

pacing site
12
lvef improvement
12
response rate
12
max ml-score
12
machine learning
8
left ventricular
8
ventricular pacing
8
cardiac resynchronization
8
resynchronization therapy
8
patient selection
8

Similar Publications

Background: Electrocardiographic imaging (ECGi) is a non-invasive technique for ventricular tachycardia (VT) ablation planning. However, it is limited to reconstructing epicardial surface activation. In-silico pace mapping combines a personalized computational model with clinical electrocardiograms (ECGs) to generate a virtual 3D pace map.

View Article and Find Full Text PDF

Background Ventricular septal pacing has long been performed using a stylet during pacemaker implantation, but with the availability of guiding catheters, His bundle pacing and left bundle branch area pacing have also been performed. However, it is not known to what extent the tip load of the ventricular lead differs when a guiding catheter is used compared with a stylet alone. In this study, the tip load was measured for different stylet stiffness and guiding catheter geometries at sites where His bundle pacing and left bundle branch area pacing were assumed.

View Article and Find Full Text PDF

Background Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetic disorder associated with an elevated risk of life-threatening arrhythmias and progressive ventricular impairment. Risk stratification is essential to prevent major adverse cardiac events (MACE). Our study aimed to investigate the incremental value of strain measured by two-dimensional speckle-tracking echocardiography in predicting MACE in ARVC patients compared to conventional echocardiographic parameters.

View Article and Find Full Text PDF

Background: Previous studies suggest the relationship between activation time (AT) and action potential duration (APD) in the heart is dependent on electrotonic coupling, but this has not been directly tested. This study assessed whether acute changes in electrical coupling, or other determinants of conduction or repolarization, modulate APD heterogeneity.

Methods And Results: Langendorff-perfused guinea pig hearts were epicardially paced and optically mapped after treatment with the gap junction uncoupler carbenoxolone, ephaptic uncoupler mannitol, ephaptic enhancer dextran 2MDa, sodium channel inhibitor flecainide, or rapid component of the delayed rectifier potassium channel inhibitor E4031.

View Article and Find Full Text PDF

The extravascular implantable cardioverter-defibrillator (EV-ICD) was developed to overcome complications associated with transvenous leads while being able to deliver anti-tachycardia pacing (ATP). The lead is implanted in the substernal space, which makes extraction a cautious procedure. We present a case of a 51-year-old women with a successful EV-ICD extraction after a lead dwell time of 4 years, which is the longest reported.

View Article and Find Full Text PDF