A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of a manually operated salad spinner centrifuge for serum separation in the healthy domestic horse (Equus caballus) and southern white rhinoceros (Ceratotherium simum). | LitMetric

Background: Field veterinarians and researchers studying wild species, such as the southern white rhinoceros, often work in remote areas with limited access to standard laboratory equipment, hindering the ability to measure serum analytes.

Objectives: The first objective was to produce an inexpensive, manually operated centrifuge that could accept standard laboratory tubes by modifying a consumer-grade salad spinner with low-cost materials. The second objective was to compare biochemistry analysis results obtained from equine and southern white rhinoceros serum separated by traditional laboratory and manual salad spinner centrifugation.

Methods: We optimized the design and serum separation protocol using non-anticoagulated equine blood. Equine and rhinoceros serum samples were separated by manual salad spinner or traditional laboratory centrifugation. Measured analytes included sodium, potassium, chloride, urea nitrogen, creatinine, phosphorous, total calcium, magnesium, glucose, total protein, albumin, globulin, creatinine kinase, aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, gamma-glutamyl transferase, total bilirubin, bicarbonate, sorbitol dehydrogenase, and triglycerides. Results obtained from serum separated by each centrifugation technique were compared by Deming regression and Bland-Altman analyses.

Results: A tube adaptor insert modeled after a swing angle rotor and a two-step salad spinner centrifugation yielded serum comparable to traditional laboratory centrifugation. For the majority of analytes, no proportional or constant biases were detected between centrifugation methods. A positive proportional bias in the measurement of ALP in serum separated by manual centrifugation was detected in both equine and rhinoceros samples.

Conclusions: Manual centrifugation with a modified salad spinner yields diagnostic quality serum suitable for the measurement of most standard biochemistry analytes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vcp.13290DOI Listing

Publication Analysis

Top Keywords

salad spinner
24
southern white
12
white rhinoceros
12
serum separated
12
traditional laboratory
12
serum
9
manually operated
8
serum separation
8
standard laboratory
8
rhinoceros serum
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!