Background: Access-site vascular injury (ASVI) remains a challenge for transfemoral transcatheter aortic valve implantation (TAVI). Although surgery is the gold standard, endovascular therapy gains growing acceptance as primary treatment option for ASVI. The aim of this study was to analyze the safety and efficacy of covered balloon-expandable stents (BXSs) placement for ASVI after transfemoral TAVI.

Methods: All patients treated with a covered BXS between January 2018 and December 2020 for access-site related bleeding complications following femoral TAVI were included in this single center retrospective study. Primary measure outcome of this study was the primary patency at 12 months. Technical success, limb clinical worsening and device related complications were additionally analyzed.

Results: During the study period, 576 percutaneous femoral TAVIs were performed. Of these, 36 patients (6%) underwent covered stent deployment for a femoral access-site complication (19 men, median age 83 years old). Procedural success was 97%. The median follow-up was 12 months (interquartile range [IQR] = 9.7, range 0-36 months). One patient was lost to follow-up. The primary patency rates at 6 and 12 months were 100% and 95% respectively. No clinical deterioration or stent fracture was described during this period.

Conclusions: Our results suggest that covered BXS deployment is a safe and effective alternative to surgery and may be a promising option for treating ASVI after femoral TAVI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2023.07.098DOI Listing

Publication Analysis

Top Keywords

covered stent
8
access-site vascular
8
vascular injury
8
aortic valve
8
valve implantation
8
single center
8
covered bxs
8
femoral tavi
8
study primary
8
primary patency
8

Similar Publications

A dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo Stent (DTS) has been developed to enhance endothelization and capture endothelial progenitor cells; however, vessel responses following DTS implantation remain unclear. Therefore, we evaluated early- and mid-term intravascular characteristics of DTS using intravascular imaging modalities. This multicenter, prospective, observational study enrolled 88 patients (95 lesions) who underwent DTS (43 patients, 48 lesions) or sirolimus-eluting Orsiro stent (SES, 45 patients, 47 lesions) implantation.

View Article and Find Full Text PDF

Background And Aim: Stent placement for biliary drainage in patients with malignant hilar biliary obstruction (MHBO) has been a topic of long-standing debate, and the best approach remains controversial. Therefore, we aimed to evaluate the efficacy, safety, and removability of multi-hole fully covered self-expandable metal stents (MH-FCSEMSs) in a preclinical experiment using swine hilar bile duct obstruction (HBDO) models and to assess the feasibility and safety of stent placement in patients with MHBO.

Methods: Three minipigs underwent endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary-radio frequency ablation (EB-RFA) to establish Bismuth type II hilar bile duct stenosis models.

View Article and Find Full Text PDF

The p48 MW HPC is a novel low-profile flow diverter covered by a hydrophilic polymer coating with antithrombogenic properties, which may reduce ischemic complications and enable a single antiplatelet therapy after insertion of the stent. In this single-center experience, we describe the efficacy of this device, focusing on the illustration of different therapeutic indications and the outcome in various clinical settings with regard to vessel anatomy, bleeding state, and aneurysm configuration. We retrospectively reviewed our database for all patients being treated with a p48 MW HPC flow diverter between February 2019 and July 2021.

View Article and Find Full Text PDF

Biophysiochemically favorable, antithrombotic and pro-endothelial coordination compound nanocoating of copper (II) with protocatechuic acid & nattokinase on flow-diverting stents.

Colloids Surf B Biointerfaces

January 2025

Institute of Biomedical Engineering, College of Medicine, Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu 610031, China. Electronic address:

Neurovascular flow-diverting stents (FDSs) are revolutionizing the paradigm for treatment of intracranial aneurysms, but they still face great challenges like post- implantation acute thrombosis and delayed reendothelialization. Surface modification is of crucial relevance in addressing such key issues. In this study, we fabricated an ultrathin nanocoating out of copper (II) together with protocatechuic acid (PCA) and nattokinase (NK) bioactive molecules on NiTi FDSs via a coordination chemistry approach, with favorable biophysiochemical interactions, to fulfill this goal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!