Radiofrequency (RF) ablation can be a source of electromagnetic interference (EMI) for cardiovascular implantable electronic devices (CIEDs). The response of CIEDs to this type of EMI can be variable and unpredictable. We report a case with an uncommon response where there was a failure to deliver pacing pulses to both atrial and ventricular pacing leads during RF ablation close to the atrial lead even when the pacemaker was set to pace asynchronously. We also explain the mechanism behind this unusual pacemaker response.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10364661PMC
http://dx.doi.org/10.19102/icrm.2023.14073DOI Listing

Publication Analysis

Top Keywords

pacemaker response
8
unexpected pacemaker
4
response
4
response catheter
4
catheter ablation
4
ablation failure
4
pacing
4
failure pacing
4
pacing pulse
4
pulse delivery
4

Similar Publications

Article Synopsis
  • Cardiac resynchronization therapy (CRT) is effective for treating heart failure but is under-researched in patients with common comorbidities like atrial fibrillation (AF).
  • The SMART registry enrolled 2035 patients to assess CRT response based on clinical outcomes over 12 months, focusing on factors like all-cause mortality, hospitalizations, and quality of life.
  • Results showed 58.9% of patients improved, but factors like age, AF, and diabetes were linked to lower CRT responsiveness, with patients having AF experiencing higher rates of hospitalizations and mortality compared to those in normal rhythm.
View Article and Find Full Text PDF

Background: Pacemaker recipients demonstrate a higher prevalence of atrial fibrillation (AF), yet the regular ventricular activation in pacemaker-dependent patients with AF presents a substantial diagnostic challenge.

Methods: A total of 310 medical practitioners completed a brief, validated survey consisting of three electrocardiograms displaying AF with ventricular pacing. Participants were instructed to identify the underlying rhythm.

View Article and Find Full Text PDF

Aim: The association of cardiac implantable electronic devices (CIED), namely pacemaker (PM), implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy with (CRT-D) or without defibrillator (CRT-P) with health-related quality of life (HRQoL) is lacking.

Methods And Results: Data from the Swedish Pacemaker and ICD Registry collected from January 2019 to February 2022 was used to analyze the responses to the European Quality of Life-5 Dimension questionnaire (EQ-5D) before and after one year of the CIED implant. Descriptive analysis was performed using Pearson's chi-square test, the analysis of variance ANOVA, the Kruskal-Wallis test and Wilcoxon signed-rank test when appropriate.

View Article and Find Full Text PDF

Zebrafish Dark-Dependent Behavior Requires Phototransduction by the Pineal Gland.

J Pineal Res

November 2024

School of Neurobiology, Biochemistry and Biophysics, The George S. Wise Faculty of Life Sciences, Tel-Aviv University, Tel Aviv, Israel.

Located dorsally underneath a thin translucent skull in many teleosts, the pineal gland is a photoreceptive organ known as a key element of the circadian clock system. Nevertheless, the presence of additional routes of photoreception presents a challenge in determining its specific roles in regulating photic-related behavior. Here, we show the importance of the pineal gland in mediating a prolonged motor response of zebrafish larvae to sudden darkness, both as a photodetector and as a circadian pacemaker.

View Article and Find Full Text PDF

Background: Syncope is a common medical condition. The reflex or neurally mediated syncope (NMS) is the most frequent type. The tilt table test (TTT) helps distinguish syncope from other common causes of complete loss of consciousness, such as epilepsy, define syncope subtypes and guide management.

View Article and Find Full Text PDF