High-power, short-duration (HPSD) radiofrequency (RF) ablation is expected to be more effective and safer than low-power, long-duration (LPLD) RF ablation in treating atrial fibrillation (AF). Given the limited data available, the findings are controversial. This meta-analysis evaluated whether the clinical effects of HPSD outweigh those of LPLD. A systematic search of PubMed, Embase, and Google Scholar databases identified studies comparing HPSD to LPLD ablation. All the analyses used the random-effects model. This analysis included 21 studies with a total of 4,169 patients. Pooled analyses revealed that HPSD was associated with a lower recurrence of atrial tachyarrhythmias (ATAs) at 1 year (relative risk [RR], 0.62; 95% confidence interval [CI], 0.50-0.78; = .00001; = 0%). Furthermore, the HPSD approach reduced the risk of AF recurrence (RR, 0.64; 95% CI, 0.40-1.01; = .06; = 86%). The HPSD approach was associated with a lower risk of esophageal thermal injury (ETI) (RR, 0.78; 95% CI, 0.58-1.04; = .09; = 73%). The HPSD strategy increased first-pass pulmonary vein (PV) isolation (PVI) and decreased acute PV reconnection (PVR), both of which were predominantly manifested in bilateral and left PVs. HPSD facilitated a reduction in procedural time, number of lesions created during PVI, and fluoroscopy time. The HPSD method reduces ETI, PVR, and recurrent AF. The HPSD approach also reduced the procedural time, number of lesions created during PVI, fluoroscopy time, and post-ablation AF relapse in 1 year, improving patient outcomes and safety.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10364668PMC
http://dx.doi.org/10.19102/icrm.2023.14072DOI Listing

Publication Analysis

Top Keywords

hpsd approach
12
hpsd
10
high-power short-duration
8
low-power long-duration
8
radiofrequency ablation
8
atrial fibrillation
8
lpld ablation
8
associated lower
8
approach reduced
8
procedural time
8

Similar Publications

Introduction: A hybrid approach with very high-power short-duration (vHPSD) posteriorly and ablation-index guided HPSD (50 W) anteriorly seems to be an optimal balance between efficiency and effectiveness for point-by-point pulmonary vein isolation (PVI). The aim of the current study is to compare vHPSD/HPSD ablation to cryoballoon ablation (CBA) in patients with symptomatic atrial fibrillation (AF).

Methods And Results: In this retrospective single-center study, we identified 110 consecutive patients who underwent their first PVI with either vHPSD/HPSD (n = 54) or CBA (n = 56).

View Article and Find Full Text PDF

Introduction: In atrial fibrillation (AF) ablation, fluoroscopy has been a standard tool for catheter guidance. However, the combination of electroanatomic mapping systems (EAMs) and intracardiac echocardiography (ICE) now allows for minimal or zero-fluoroscopy procedures. Concurrently, high-power short-duration (HPSD) ablation has emerged as a promising technique, offering enhanced resistive heating while reducing conductive heating.

View Article and Find Full Text PDF
Article Synopsis
  • The peQasus study evaluates the safety and effectiveness of a new temperature-controlled high-power short-duration (HPSD) radiofrequency catheter (QDOT Micro) for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF).
  • Conducted across 15 centers in Europe, the study involved 1,023 patients and compared outcomes between a very HPSD technique and a hybrid approach.
  • Results indicated complete PVI success, a mean procedure time of about 98 minutes, and a similar safety profile for both techniques, with 12-month arrhythmia-free survival rates around 77%.
View Article and Find Full Text PDF
Article Synopsis
  • * The study compares a new treatment technique, high-power short-duration pulmonary vein isolation (HPSD-PVI), with traditional methods to see which is more effective in preventing recurrent atrial tachyarrhythmia (ATA).
  • * Analyzing 969 patients, the research found that different factors predicted recurrence for each technique, with the HPSD-PVI group showing a trend towards lower recurrence rates compared to the conventional method.
View Article and Find Full Text PDF
Article Synopsis
  • The study investigates a new approach combining high-power short-duration (HPSD) and very high-power short-duration (vHPSD) ablation techniques for superior vena cava isolation (SVCI) in atrial fibrillation patients.
  • Compared to a conventional middle-power, middle-duration (MPMD) ablation, the combined approach (50W/90W) showed significantly shorter procedural times, reduced RF duration and energy use, while maintaining similar success rates and safety profiles.
  • The results indicate that the 50W/90W technique is effective and safe, with no complications noted during the procedures in either group.