A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study. | LitMetric

AI Article Synopsis

  • The study aimed to compare the accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG) for complete-arch digital implant impressions in real patients.
  • A total of 11 patients had their dental implants measured using both technologies, and results showed that SPG was significantly more accurate than IOS in capturing linear and angular measurements.
  • The researchers concluded that while SPG is a promising method for digital impressions, careful prototyping is necessary before producing final dental prostheses.

Article Abstract

Objectives: To assess accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG), complete-arch digital implant impressions in vivo.

Materials And Methods: Consecutive patients needing implant-supported screw-retained zirconia complete-arch fixed-dental prostheses (ISZ-FDP) were recruited. For each patient, three impressions were taken: IOS, SPG (tests), and open-tray plaster (reference). Linear (ΔX, ΔY, and ΔZ), three-dimensional (ΔEUC), and angular deviations (ΔANGLE) were evaluated and stratified according to scanning technology for each implant. Potential effects of impression device (IOS and SPG), arch (maxilla and mandible), and implant number (4 and 6) were evaluated through multivariable analysis. Significance level was set at .05.

Results: A total of 11 complete arches (5 maxillae, 6 mandibles) in 11 patients were rehabilitated with ISZ-FDPs supported by 4 (n = 8) and 6 implants (n = 3). A total of 50 implants and 100 implant positions were captured by two investigated devices and compared to respective reference (mean ΔEUC IOS 137.2, SPG 87.6 μm; mean ΔANGLE 0.79, 0.38°). Differences between measurements (SPG-IOS) were computed for each implant, with negative values indicating better SPG accuracy. Significant mean ΔEUC difference of -49.60 μm (p = .0143; SD 138.15) and mean ΔANGLE difference of -0.40° (p < .0001; SD 0.65) were observed in favor of SPG. Multivariable analysis showed significant effect on ΔEUC (p = .0162) and ΔANGLE (p = .0001) only for impression devices, with SPG performing better.

Conclusions: SPG experienced significantly higher linear and angular accuracy. No effect of type of arch or implant number was detected. Higher extreme deviations were experienced for IOS. SPG can be feasible for complete-arch digital impressions with caution, and rigid prototype try-in is recommended before screw-retained prosthesis manufacturing.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.14141DOI Listing

Publication Analysis

Top Keywords

complete-arch digital
8
digital implant
8
intraoral optical
8
optical scanning
8
ios spg
8
implant
6
spg
5
accuracy complete-arch
4
implant impression
4
impression intraoral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!