Aim: Comparing intraocular pressure (IOP) measurements using Goldmann applanation prism and TonoSafe® in the population without signs of glaucoma.
Material And Methods: Patients with no ocular pathologies, except ametropia (until ± 4 D) or IOP of <30 mm Hg without signs of glaucoma by optic disc structural analysis by fundus biomicroscopy. The IOP was measured sequentially using the traditional cone and the TonoSafe®, according to a randomization list to determine which device would be used first. The measurements from the right and left eyes were compared separately. Since there was no statistical difference, both eyes were considered in this study.
Results: A total of 385 eyes of 194 patients with a mean age of 66.4 ± 11.2 years old were included. The mean IOP with conventional prism was 14.2 ± 3.6 and 14.3 ± 3.6 mm Hg with TonoSafe. Differences were not statistically significant by the Wilcoxon test ( = 0.3). The median was 14.0 mm Hg for both groups. The mean difference between measurements was 0.04 mm Hg, with the median equal to zero. There was no statistical difference in IOP readings according to which device was the first measurement.
Conclusion: No statistical difference was found in IOP was measured with conventional prism or TonoSafe® in the population without signs of glaucoma.
Clinical Significance: The data provided by our study support the efficacy and safety of the disposable tonometer compared to the Goldman tonometer in measuring IOP in patients without glaucoma.
How To Cite This Article: Soares PHA, Santos RDO, Filho CRADM, Goldmann Applanation Tonometry: Comparison of Intraocular Pressure Values Obtained with Disposable Tip and Conventional Applanation Prism in the Population without Clinical Signs of Glaucoma. J Curr Glaucoma Pract 2023;17(2):75-78.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10357021 | PMC |
http://dx.doi.org/10.5005/jp-journals-10078-1401 | DOI Listing |
Graefes Arch Clin Exp Ophthalmol
December 2024
Kaiya Eye Clinic, Hamamatsu, Shizuoka, Japan.
Purpose: Little is known about the effects of ambient atmospheric pressure (AP) on intraocular pressure (IOP) under ordinary conditions. This study aimed to investigate the effects of AP on Goldmann applanation tonometer-measured IOP (GAT-IOP) in normal eyes under everyday atmospheric conditions adjusting for effects of possible confounding factors including other climatic factors.
Methods: Data obtained from 2,431 normal healthy eyes of 2,431 subjects (mean age: 56.
J Clin Med
November 2024
2nd Department of Ophthalmology, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
Intraocular pressure (IOP) readings using three different methods (Goldmann applanation tonometry (GAT), Corvis ST, and iCare) were compared in patients who underwent penetrating keratoplasty (PK). : An observational cross-sectional study with prospective recruitment of patients was conducted. IOP measurements were acquired using GAT, iCare, and Corvis (including both uncorrected IOP (CVS-IOP) and biomechanical IOP (bIOP)), and the agreement among methods was analyzed using Bland-Altman plots.
View Article and Find Full Text PDFInt Ophthalmol
December 2024
Clinic of Ophthalmology, Mersin State Hospital, Mersin, Turkey.
Purpose: To evaluate the effect of upper eyelid blepharoplasty with or without the removal of a strip of orbicularis oculi muscle on corneal topographic parameters, anterior segment parameters, intraocular pressure, and ocular biometry.
Method: This prospective study examined 428 eyes of 214 patients with dermatochalasis. Patients were divided into two groups randomly: those who underwent orbicularis oculi muscle excision (Group 1) during blepharoplasty and those who did not (Group 2).
Ophthalmol Glaucoma
November 2024
Department of Ophthalmology, University of Sao Paulo School of Medicine, Sao Paulo, São Paulo 01246-903, Brazil.
Purpose: To investigate the agreement between the Icare HOME tonometer and the Goldmann Applanation Tonometry (GAT) in assessing the Peak Intraocular Pressure during the Water-Drinking Test (WDT).
Design: Prospective cross-sectional study.
Subjects: 79 eyes of 41 open-angle glaucoma patients were included in the study.
Klin Monbl Augenheilkd
November 2024
Surgery, University of Santiago de Compostela, Santiago de Compostela, Spain.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!