Background: Ankle fractures are common injuries in the young and elderly populations. To prevent post-traumatic arthritis, an anatomic reconstruction of the ankle structure is mandatory. Open reduction and internal fixation is the treatment of choice among orthopaedics. Conventional plates allow stability of the fracture if bone quality is present. Locking plates might offer an advantage for the treatment of lateral malleolar fracture in patients with comminution, severe instability, distal fractures, or osteoporotic bone. Our hospital introduced a new locking plate for fracture of the distal fibula.
Aim: To evaluate locking plates in terms of outcomes and complications in young and elderly patients.
Methods: We retrospectively reviewed a total of 67 patients treated for displaced distal fibula fractures. Demographic data, number of comorbidities, use of inter fragmentary screw, complication, time of fracture healing, partial or full weight bearing, and reoperation were recorded for all patients. Clinical outcome was assessed by the American Orthopedic Foot and Ankle Society clinical scoring system. Radiographs were obtained at 4, 8, 12, 16, 20, and 24 wk until radiographic union was obtained.
Results: All patients displayed complete bony union on radiographic assessment, and no patients developed any serious complications. We observed two superficial infections, one delayed wound healing, and two plate intolerances. Significant differences were observed between the two age groups in terms of radiographic healing (11.9 wk in younger patients 13.7 wk in older patients; = 0.011) and in the American Orthopedic Foot and Ankle Society score at 6 mo after surgery (88.2 in younger patients 86.0 in older patients; = 0.001) and at 12 mo after surgery (92.6 in younger patients 90.0 in older patients; = 0.000).
Conclusion: Locking plates provide a stable and rigid fixation in multifragmentary and comminuted fractures or in the presence of poor bone quality.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10359748 | PMC |
http://dx.doi.org/10.5312/wjo.v14.i7.540 | DOI Listing |
Vet Comp Orthop Traumatol
December 2024
School of Veterinary Medicine, Murdoch University, Perth, Australia.
Vet Comp Orthop Traumatol
December 2024
CNsurgery, Liss, Hampshire, United Kingdom of Great Britain and Northern Ireland.
Background: Achieving bony union in scaphoid nonunion fractures is challenging. Various bone grafts have been studied using headless compression screws (HCS) fixation. However, the impact of bone graft choice on bone healing with volar locking plates (VLP) use is less clear.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Jinshan Branch, Jinshan District Central Hospital, Shanghai, 201500, China.
Background: The lateral locking plate for the proximal humerus is currently the most commonly used surgical procedure for the treatment of elderly proximal humeral comminuted fractures. Previous studies have found that the rate of postoperative complications in patients of proximal humerus fractures with medial column involvement is relatively high. Through biomechanical methods, this study aims to investigate the effectiveness of the conventional lateral locking plate fixation along with the addition of the metacarpal supporting plate on the medial column in the treatment for proximal humeral fractures involving the medial column.
View Article and Find Full Text PDFInjury
December 2024
Department of Orthopaedics, Larnaca General Hospital, State Health Services Organisation, Larnaca, Cyprus.
The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!