Aim: To compare subepithelial connective tissue grafts (SCTG) versus guided bone regeneration (GBR) for the treatment of small peri-implant dehiscence defects in terms of profilometric (primary outcome), clinical, and patient-reported outcome measures (PROMs).
Methods: Sixteen patients who presented with small buccal bone dehiscences (≤3 mm) following single implant placement were recruited. Following implant placement, buccal bone defect sites were randomly treated either with a SCTG or GBR. Six patients who lacked bone dehiscences after implant placement were assigned to a negative control. Transmucosal healing was applied in all patients. Patients were examined prior (T1) and after (T2) implant placement, at suture removal (T3), at implant impression (T5), at crown delivery (T6), and 12 (T7) months after crown delivery. Measurements included profilometric outcomes, marginal bone levels, buccal bone and soft tissue thickness, PROMs, and clinical parameters. All data were analyzed descriptively.
Results: The median changes in buccal contour as assessed by profilometric measures between T1 and T5 showed a decrease of 1.84 mm for the SCTG group and 1.06 mm for the GBR group. Between T2 and T7, the median change in the buccal contour amounted to 0.45 mm for SCTG and -0.94 mm (=loss) for GBR. Patients' pain perception tended to be higher in SCTG than in GBR. All peri-implant soft tissue parameters showed healthy oral tissues and no clinically relevant differences between groups.
Conclusion: Within the limitations of this pilot study, treating small peri-implant dehiscence defects with a SCTG might be a viable alternative to GBR. The use of a SCTG tended to result in more stable profilometric outcomes and comparable clinical outcomes to GBR. However, patient-reported outcome measures tended to favor GBR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/clr.14140 | DOI Listing |
Multimed Man Cardiothorac Surg
January 2025
Congenital Heart Center, Division of Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA.
The Berlin Heart EXCOR is a pulsatile paracorporeal ventricular assist device (VAD) for neonates, infants, children and adults with congenital or acquired severe ventricular dysfunction. Berlin Heart EXCOR VADs are routinely used as either a bridge to a cardiac transplantation, or occasionally as a bridge to ventricular recovery. Our programmatic philosophy is to bridge neonates and infants with functionally univentricular ductal-dependent systemic circulation or functionally univentricular ductal-dependent pulmonary circulation who are at high risk for staged palliation because of important cardiac risk factors with a single-ventricle VAD (sVAD) as a bridge to a cardiac transplant.
View Article and Find Full Text PDFJ Endocrinol
January 2025
U Iwaniec, Skeletal Biology Laboratory, Oregon State University, Corvallis, United States.
Leptin increases focal inflammation and osteolysis induced by polyethylene particles in leptin-deficient ob/ob mice suggesting the adipokine, an important immune modulator, contributes to orthopedic implant failure. Focal inflammation leads to bone loss at distant skeletal sites, and it is plausible that leptin also contributes to this response. We tested this possibility in 6-week-old female ob/ob mice (6-8/group) by evaluating bone architecture, turnover, and gene expression 12 days following surgical placement of polyethylene particles over calvaria.
View Article and Find Full Text PDFPlast Reconstr Surg Glob Open
January 2025
Instituto Médico Cervantes, São Paulo, Brazil.
Background: Mastopexy combined with implant placement is a complex cosmetic surgery due to the dual nature of the procedure. Various mammoplasty techniques and implant types add to its intricacy. This study aimed to evaluate the effectiveness of an internal breast lift in correcting pseudoptosis, grade 1 breast ptosis, and asymmetries, thereby offering a safer alternative with reduced morbidity and avoiding the creation of an inverted T scar.
View Article and Find Full Text PDFJ Neurol Surg B Skull Base
February 2025
Department of Neurosurgery, UC San Diego Medical Center, San Diego, California, United States.
Many patients with neurofibromatosis type 2 (NF2) suffer from sensorineural hearing loss, and associated cochlear nerve compromise in NF2 patients makes auditory brainstem implant (ABI) an attractive treatment option. The long-term outcomes and benefits of the device are still being explored. A retrospective review was conducted for 11 ABI recipients at a single-institution tertiary center between November 2017 and August 2022.
View Article and Find Full Text PDFJ Neurointerv Surg
January 2025
Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany
Background: Intrasaccular devices have broadened treatment options for wide necked aneurysms. This study presents the preliminary experience with the Artisse 2.0 device.