Muscle strength assessment is important in predicting clinical and functional outcomes in many disorders. Manual muscle testing, although commonly used, offers suboptimal accuracy and reliability. Isokinetic dynamometers (IKDs) have excellent accuracy and reliability; but are bulky and expensive, offering limited accessibility. This study aimed to design a portable dynamometer that is accessible, accurate and reliable, and to validate the device in a general population. The portable articulated dynamometry system (PADS) is a portable device with an embedded high-precision load cell, designed to measure muscle strength with optimal accuracy. Seventy-two participants underwent maximal isometric and isokinetic knee extensor torque measurement with the PADS and IKD, respectively. The PADS results were cross-validated against IKD results using change in mean (CIM). Interrater and intra-rater reliabilities were assessed using intraclass correlation coefficients, standard error of measurement, and minimal detectable change. The PADS maximal knee extensor strength results were not significantly different from those by IKD (CIM: - 2.13 Nm; 95% CI - 4.74, 0.49 Nm). The PADS showed interrater reliability (Pearson's r: 0.958; ICC: 0.979; SEM: 5.51%) and excellent intra-rater reliability (Pearson's r: 0.912; ICC: 0.954; SEM: 8.38%). The proposed PADS may be an effective alternative to IKD, offering good accuracy, reliability, and potentially better accessibility.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10363537 | PMC |
http://dx.doi.org/10.1038/s41598-023-39062-0 | DOI Listing |
J Sports Sci
December 2024
Department of Biomechanics, Performance Analysis and Strength & Conditioning, Olympic Training & Testing Centre Westphalia, Dortmund, Germany.
The difficulties of rehabilitation after anterior cruciate ligament (ACL) injuries, subsequent return-to-sport (RTS) let alone achieving pre-injury performance, are well known. Isokinetic testing is often used to assess strength capacities during that process. The aim of the present machine learning (ML) approach was to examine which isokinetic data differentiates athletes post ACL reconstruction (ACLR) and healthy controls.
View Article and Find Full Text PDFWorld J Surg Oncol
December 2024
Department of Physiotherapy, Universidad Cardenal Herrera-CEU, CEU Universities, Valencia, Spain.
Background: Endoprosthetic knee replacement using megaprostheses has become a common strategy for preserving joint function in patients with distal femur tumors. While existing literature has primarily focused on surgical techniques, complications, and implants, recent improvements in patient survival rates have sparked increased interest in the long-term functional outcomes associated with this treatment.
Methods: This case-control study evaluated functional outcomes-Timed Up and Go (TUG), 6-Minute Walk Test (6MWT), knee flexor and extensor muscle strength, and sagittal knee range of motion-and health-related quality of life (SF-36) between patients with distal femoral megaprostheses (n = 31) and healthy controls (n = 48).
Eur J Appl Physiol
December 2024
Inter-university Laboratory of Human Movement Sciences, Univ. Savoie Mont Blanc, EA 7424, 73000, Chambéry, France.
Purpose: Alpine skiing races are physically demanding events characterized by numerous repeated near-maximal activations of the lower limb muscles. Although this type of task is known to induce neuromuscular fatigue, electromyographic activity (EMG) adaptations after repeated maximal-intensity skiing have not been previously investigated.
Methods: Six skiers completed a 6-turns section with (FAT) and without performing 30 giant slalom (GS) turns (CONT).
Am J Physiol Regul Integr Comp Physiol
December 2024
Muscle Physiology Laboratory, Department of Kinesiology, University of Massachusetts Amherst, MA 01003, USA.
The cause and consequences of inosine monophosphate (IMP) formation when ATP declines during muscular contractions are not fully understood. The purpose of this study was to examine the role of IMP formation in the maintenance of the Gibbs free energy for ATP hydrolysis (∆G) during dynamic contractions of increasing workload, and the implications of ATP loss . Eight males (27.
View Article and Find Full Text PDFJ Strength Cond Res
December 2024
Department of Sports Science and Physical Education, Nord University, Levanger, Norway.
Gundersen, AH, van den Tillaar, R, Falch, HN, Fredriksen, AB, and Larsen, S. A biomechanical comparison between conventional, sumo, and hex-bar deadlifts among resistance trained women. J Strength Cond Res XX(X): 000-000, 2024-The deadlift is a multijoint exercise frequently used to strengthen the lower extremities and spinal erectors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!