Color-Changing Reflection Hologram for Quality Assurance of Therapeutic Ultrasound Systems.

ACS Appl Mater Interfaces

Centre for Industrial and Engineering Optics, School of Physics, Clinical and Optometric Sciences, Technological University Dublin, Grangegorman Campus, Central Quad, Grangegorman Lower, D07 ADY7 Dublin, Ireland.

Published: August 2023

The acoustic output of clinical therapeutic ultrasound equipment requires regular quality assurance (QA) testing to ensure the safety and efficacy of the treatment and that any potentially harmful deviations from the expected output power density are detected as soon as possible. A hologram, consisting of a reflection grating fabricated in an acrylate photopolymer film, has been developed to produce an immediate, visible, and permanent change in the color of the reconstructed hologram from red to green in response to incident ultrasound energy. The influence of the therapeutic ultrasound insonation parameters (exposure time, ultrasound power density, and proximity to the point of maximum acoustic pressure) on the hologram's response has been investigated for two types of therapeutic ultrasound systems: a sonoporation system and an ultrasound physiotherapy system. Findings show that, above a switching temperature of 45 °C, the ultrasound-induced temperature rise produces a structural change in the hologram, which manifests as a visible color change. The area of the color change region correlates with the ultrasound exposure conditions. The suitability of the hologram as a simple and quick QA test tool for therapeutic ultrasound systems has been demonstrated. A prototype ultrasound testing unit which facilitates user-friendly, reproducible testing of the holograms in a clinical setting is also reported.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10401507PMC
http://dx.doi.org/10.1021/acsami.3c06139DOI Listing

Publication Analysis

Top Keywords

therapeutic ultrasound
20
ultrasound systems
12
ultrasound
10
quality assurance
8
power density
8
color change
8
hologram
5
therapeutic
5
color-changing reflection
4
reflection hologram
4

Similar Publications

Background: Magnetic resonance-guided focused ultrasound (MRgFUS) thalamotomy of ventral intermediate (Vim) nucleus is useful to treat drug-resistant tremor-dominant Parkinson's disease (TdPD), but tremor relapse may occur. Predictors of relapse have been poorly investigated so far.

Objective: The aim of this study is to evaluate the role of clinico-demographic, procedural, and neuroradiological variables in determining clinical response, relapse, and adverse events (AEs) in TdPD after MRgFUS Vim-thalamotomy.

View Article and Find Full Text PDF

Lumbar Erector Spinae Plane Block Provides Effective Postoperative Analgesia in Hip Fracture Surgery.

J Coll Physicians Surg Pak

January 2025

Department of Orthopaedics and Traumatology, Faculty of Medicine, Sakarya University, Sakarya, Turkiye.

Objective: To compare the postoperative analgesic effectiveness of ultrasound-guided lumbar erector spinae plane (LESP) block with lumbar plexus block (LPB) in patients operated for proximal femur fractures.

Study Design: A randomised controlled trial. Place and Duration of the Study: Sakarya Training and Research Hospital Operation Theatre, Sakarya, Turkiye, between January and June 2023.

View Article and Find Full Text PDF

Background: Lower urinary tract disease is a common clinical condition in dogs, usually presenting with dysuria, pollakiuria and haematuria. Diabetes mellitus is a predisposing factor for urinary tract infection in both humans and dogs and does not necessarily present with clinical signs. In this case report, we describe for the first time a case of cystitis glandularis in a dog with diabetes mellitus, associated with Escherichia coli urinary tract infection.

View Article and Find Full Text PDF

The important role of the histone acetyltransferases p300/CBP in cancer and the promising anticancer effects of p300/CBP inhibitors.

Cell Biol Toxicol

January 2025

Department of Ultrasound, Shengjing Hospital of China Medical University, 110004, Shenyang, Liaoning, China.

Histone acetyltransferases p300 (E1A-associated protein p300) and CBP (CREB binding protein), collectively known as p300/CBP due to shared sequence and functional synergy, catalyze histone H3K27 acetylation and consequently induce gene transcription. p300/CBP over-expression or over-activity activates the transcription of oncogenes, leading to cancer cell growth, resistance to apoptosis, tumor initiation and development. The discovery of small molecule inhibitors targeting p300/CBP histone acetyltransferase activity, bromodomains, dual inhibitors of p300/CBP and BRD4 bromodomains, as well as proteolysis-targeted-chimaera p300/CBP protein degraders, marks significant progress in cancer therapeutics.

View Article and Find Full Text PDF

To investigate how PD-L1 monoclonal antibodies (mAbs) affect the left ventricular function in mice with myocardial infarction (MI) and through what mechanisms they exert their effects. In vivo experiments were conducted using 27 female BALB/c mice, which were divided equally into 3 groups. Cardiac function was assessed by ultrasound.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!