Purpose: A possible pathway behind gadolinium retention in brain is leakage of contrast agents from blood to cerebrospinal fluid and entry into brain along perivascular (glymphatic) pathways. The object of this study was to assess for signs of gadolinium retention in brain 4 weeks after intrathecal contrast enhanced MRI.

Methods: We prospectively applied standardized T1 mapping of the brain before and 4 weeks after intrathecal administration of 0.5 mmol gadobutrol in patients under work-up of cerebrospinal fluid circulation disorders. Due to methodological limitations, a safety margin for percentage change in T1 time was set to 3%. Region-wise differences were assessed by pairwise comparison using t-tests and forest plots, and statistical significance was accepted at .05 level (two-tailed).

Results: In a cohort of 76 participants (mean age 47.2 years ± 17.9 [standard deviation], 47 women), T1 relaxation times remained unchanged in cerebral cortex and basal ganglia 4 weeks after intrathecal gadobutrol. T1 was reduced from 1082 ± 46.7 ms to 1070.6 ± 36.5 ms (0.98 ±2.9%) (mean [standard deviation]) (p=0.001) in white matter, thus within the pre-defined 3% safety margin. The brain stem and cerebellum could not be assessed due to poor alignment of posterior fossa structures at scans from different time points.

Conclusion: Gadolinium retention was not detected in the cerebral hemispheres 4 weeks after an intrathecal dose of 0.5 mmol gadobutrol, implying that presence of contrast agents in cerebrospinal fluid is of minor importance for gadolinium retention in brain.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10425514PMC
http://dx.doi.org/10.1007/s00234-023-03198-7DOI Listing

Publication Analysis

Top Keywords

gadolinium retention
20
retention brain
16
weeks intrathecal
16
cerebrospinal fluid
12
intrathecal gadobutrol
8
contrast agents
8
brain weeks
8
mmol gadobutrol
8
safety margin
8
[standard deviation]
8

Similar Publications

Innovative Perspectives on Metal Free Contrast Agents for MRI: Enhancing Imaging Efficacy, and AI-Driven Future Diagnostics.

Acta Biomater

January 2025

Institute of Smart Biomedical Materials, School of Materials Science and Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, PR China. Electronic address:

The U.S. Food and Drug Administration (FDA) has issued a boxed warning and mandated additional safety measures for all gadolinium-based contrast agents (GBCAs) used in clinical magnetic resonance imaging (MRI) due to their prolonged retention in the body and associated adverse health effects.

View Article and Find Full Text PDF

Background: We examined chronic gadolinium retention impact on gene expression in the mouse central nervous system (CNS) after injection of linear or macrocyclic gadolinium-based contrast agents (GBCAs).

Methods: From 05/2022 to 07/2023, 36 female mice underwent weekly intraperitoneal injections of gadodiamide (2.5 mmol/kg, linear), gadobutrol (2.

View Article and Find Full Text PDF

The aquaporin-4 (AQP4) water channel is essential in neurofluid dynamics. AQP4 loss impairs solute exchange between the cerebrospinal fluid (CSF) and interstitial fluid (ISF). However, whether AQP4 expression affects solute clearance from the CSF space to the extracranial space remains unclear.

View Article and Find Full Text PDF

Magnetic resonance imaging contrast agents can enhance diagnostic precision but often face limitations such as short imaging windows, low tissue specificity, suboptimal contrast enhancement, or potential toxicity, which affect resolution and long-term monitoring. Here, we present a protein contrast agent based on lanmodulin, engineered with a single-point mutation at position 108 from N to D to yield maximum gadolinium binding sites. After loading with Gd ions, the resulting protein complex, LanND-Gd, exhibits efficient renal clearance, high relaxivity, and prolonged renal retention compared to commercial agents.

View Article and Find Full Text PDF

Introduction: This survey investigates brain MRI practices for isolated GHD among Pediatric Endocrine Society (PES) members, focusing on gadolinium-based contrast agents (GBCAs) versus non-contrast MRI.

Methods: A 15-question survey was distributed to 1,553 PES members, capturing data on GBCA usage, non-contrast imaging access, and awareness of gadolinium retention.

Results: A total of 85% of respondents routinely order brain MRIs for isolated GHD, with 60% using GBCAs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!