A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The risk of clinical misinterpretation of HbA1c: Modelling the impact of biological variation and analytical performance on HbA1c used for diagnosis and monitoring of diabetes. | LitMetric

Background: The validity of clinical interpretation of HbA1c depends on the analytical performance of the method and the biological variation of HbA1c in patients. The contribution of non-glucose related factors to the biological variation of HbA1c (NGBVA1c) is not known. This paper explores the cumulative impact of analytical errors and NGBVA1c on the risk of misinterpretation.

Methods: A model has been developed to predict the risk of misinterpretation of HbA1c for diagnosis and monitoring with variables for analytical performance and levels of NGBVA1c.

Results: The model results in probabilities of misinterpretation for a given HbA1c.

Example: for an HbA1c 43 mmol/mol (6.1%), bias 1 mmol/mol (0.09%), CV 3% (2%) used for diagnosis, the probabilities of misinterpretation range from 1 to 19% depending on the contribution of NGBVA1c to the biological variation of HbA1c.

Conclusions: In addition to analytical bias and imprecision, NGBVA1c contributes to the risk of misinterpretation, but the relative impact is different per clinical application of HbA1c. For monitoring, imprecision is the predominating factor, for diagnosis both biological variation and analytical bias. Given the increasing use of HbA1c for diagnosis, increase of knowledge on NGBVA1c, decrease of analytical bias, and awareness of the risk of misinterpretation are required.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2023.117495DOI Listing

Publication Analysis

Top Keywords

biological variation
20
analytical performance
12
hba1c diagnosis
12
risk misinterpretation
12
analytical bias
12
hba1c
9
misinterpretation hba1c
8
variation analytical
8
diagnosis monitoring
8
variation hba1c
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!