Background: Balloon trocar devices have been utilized in several surgical cases to reach a difficult-to-access location, achieve hemostasis, and obtain safe, efficient surgery.

Objective: Highlight the balloon trocar dissection device in a novel technique of scalp flap elevation for tissue expander placement.

Methods: The pocket for the tissue expander was determined at the scalp. A 2 cm vertical incision was made. A 12 mm balloon trocar is then introduced and insufflated. Through the trocar, endoscopic light is then inserted. Scalp flap elevation was performed with the device. The exact location of the pocket was seen with the lumination of endoscopic light.

Results: The balloon trocar dissection device provides easy scalp flap elevation and bleeding control. With the help of endoscopic light, the pocket for the expander was created precisely.

Conclusion: The balloon trocar device is simple, effective, low-cost equipment for tissue expander placement in the scalp.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000009526DOI Listing

Publication Analysis

Top Keywords

balloon trocar
24
scalp flap
16
flap elevation
16
trocar dissection
12
dissection device
12
tissue expander
12
endoscopic light
8
trocar
7
balloon
6
device
5

Similar Publications

Minimally invasive balloon-reduction of acute Hill-Sachs-lesions and impression fractures after shoulder dislocation - an experimental approach.

J Shoulder Elbow Surg

November 2024

University Centre for Orthopaedic, Trauma- and Plastic Surgery (OUPC), University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany; Centre for Translational Bone, Joint and Soft Tissue Research, Technical University Dresden, Dresden, Germany.

Background: The shoulder is the joint most often affected by dislocations. It is known that bony defects of the glenoid and/or humerus can lead to recurrent dislocations even after arthroscopic shoulder stabilization. To prevent recurrent instability, it appears reasonable to reduce fresh and larger Hill-Sachs lesions (off-track lesions).

View Article and Find Full Text PDF
Article Synopsis
  • - Hemorrhage is the main cause of preventable death in trauma situations, leading to military and civilian advancements in medical practices, particularly through the use of tourniquets to manage extremity bleeding and save lives.
  • - While tourniquets have significantly decreased deaths from bleeding in military settings, noncompressible hemorrhage still poses a major risk, especially before patients receive definitive medical care.
  • - The study explores using a small, disposable pressure monitor during resuscitative endovascular balloon occlusion of the aorta (REBOA) to enhance blood pressure monitoring, facilitate better resuscitation practices, and reduce the need for blood products in extreme environments.
View Article and Find Full Text PDF

Purpose: Percutaneous lesioning-techniques for treating refractory Trigeminal Neuralgias not amenable to Micro-Vascular Decompression remain useful in neurosurgical practice. Success, avoidance of complications and reduction of side-effects depend on the accurate location of the lesion-maker especially for Radio-Frequency-Thermo-Rhizotomy (RF-Th-Rh). Added to X-ray-guidance, Intra-Operative Neurophysiology can be of significant help to achieve optimal accuracy of the surgery.

View Article and Find Full Text PDF

Minimally Invasive Sinus Augmentation: A Systematic Review.

Clin Implant Dent Relat Res

October 2024

Division of Periodontology, the Ohio State University, College of Dentistry, Columbus, Ohio, USA.

Aim: Technology improvement and a better understanding of sinus anatomy and wound healing in the past decade have allowed the development of minimally invasive surgical techniques. This systematic review focused on identifying and describing these techniques for vertical and lateral sinus augmentation (VSA and LSA).

Materials And Methods: Electronic and hand search were conducted to screen the literature published from January 2003 to May 2024.

View Article and Find Full Text PDF

Digital versus speculum-based balloon catheter insertion for labor induction: a systematic review and meta-analysis.

Am J Obstet Gynecol MFM

December 2024

Department of Obstetrics and Gynaecology, Monash University, Faculty of Medicine, Nursing and Health Sciences, Monash Medical Centre, 246 Clayton Rd, Clayton, Victoria 3168 Australia (Seo, Davies-Tuck, Warty, Smith, and Palmer); Monash Women's, Monash Health, 246 Clayton Rd, Clayton, Victoria Australia (Palmer).

Article Synopsis
  • The study examines the effectiveness, safety, and acceptability of two methods for cervical preparation prior to labor induction: digital insertion vs. speculum-based insertion of catheter balloons.
  • It utilized various medical databases to find randomized controlled trials that met specific criteria, focusing on viable singleton pregnancies and excluding studies that didn't involve cervical balloons.
  • The results indicated that while digital insertion was generally less painful and had comparable maternal satisfaction, overall outcomes showed no significant difference between the two methods, despite some concerns over study biases.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!