Scalable High Tensile Modulus Composite Laminates Using Continuous Carbon Nanotube Yarns for Aerospace Applications.

ACS Appl Nano Mater

FAMU-FSU College of Engineering, High-Performance Materials Institute, Florida State University, 2005 Levy Avenue, Tallahassee, Florida 32311, United States.

Published: July 2023

An approach is established for fabricating high-strength and high-stiffness composite laminates with continuous carbon nanotube (CNT) yarns for scaled-up mechanical tests and potential aerospace structure applications. Continuous CNT yarns with up to 80% degree of nanotube alignment and a unique self-assembled graphitic CNT packing result in their specific tensile strengths of 1.77 ± 0.07 N/tex and an apparent specific modulus of 92.6 ± 3.2 N/tex. Unidirectional CNT yarn reinforced composite laminates with a CNT concentration of greater than 80 wt % and minimal microscale voids are fabricated using filament winding and aerospace-grade resin matrices. A specific tensile strength of up to 1.71 GPa/(g cm) and specific modulus of 256 GPa/(g cm) are realized; the specific modulus exceeds current state-of-the-art unidirectional carbon fiber composite laminates. The specific modulus of the laminates is 2.76 times greater than the specific modulus of the constituent CNT yarns, a phenomenon not observed in carbon fiber reinforced composites. The results demonstrate an effective approach for fabricating high-strength CNT yarns into composites for applications that require specific tensile modulus properties that are significantly beyond state-of-the-art carbon fiber composites and potentially open an unexplored performance region in the Ashby chart for composite material applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10353548PMC
http://dx.doi.org/10.1021/acsanm.3c01266DOI Listing

Publication Analysis

Top Keywords

specific modulus
20
composite laminates
16
cnt yarns
16
specific tensile
12
carbon fiber
12
tensile modulus
8
laminates continuous
8
continuous carbon
8
carbon nanotube
8
fabricating high-strength
8

Similar Publications

Time-dependent effects of ethanol-glycerin embalming on iliotibial band biomechanics.

J Mech Behav Biomed Mater

January 2025

Fraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany; Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria; Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany; Department of Anatomy, University of Otago, Dunedin, New Zealand.

When conducting biomechanical testing or clinical training using embalmed human soft tissues, it is essential to understand their impact on biomechanical properties and their time dependence. Previous studies have investigated this influence, but specific variations over different embalming durations have not been thoroughly addressed to date. Ninety-seven human iliotibial band specimens were obtained from nine donors.

View Article and Find Full Text PDF

This work is focused on the impact of temperature and deformation on the mechanical properties, specifically the elastic modulus () of the amorphous regions in semicrystalline polymers, using polypropylene as a case study. It has been shown that increasing temperature results in an decrease due to the enhanced mobility of polymer chains, triggered by the activation of α relaxation processes within the crystalline component. Consequently, rising temperature reduces the "stiffening" effect of the crystalline regions on the interlamellar layers.

View Article and Find Full Text PDF

Background: Electrographic flow (EGF) mapping allows for the visualization of global atrial wavefront propagations. One mechanism of initiation and maintenance of atrial fibrillation (AF) is stimulation from EGF-identified focal sources that serve as driver sites of fibrillatory conduction. Electrographic flow consistency (EGFC) further quantifies the concordance of observed wavefront patterns, indicating that a healthier substrate shows more organized wavefront propagation and higher EGFC.

View Article and Find Full Text PDF

Biomimetic bone cartilage scaffolds based on trilayer methacrylated hydroxyapatite/GelMA composites for full-thickness osteochondral regeneration.

Int J Biol Macromol

January 2025

Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, The School of Pharmacy, Fujian Medical University, Fuzhou 350122, China. Electronic address:

Since cartilage injury is often accompanied by subchondral bone damage, conventional single-phase materials cannot accurately simulate the osteochondral structure or repair osteochondral injury. In this work, a gradient gelatin-methacryloyl (GelMA) hydrogel scaffold was constructed by a layer-by-layer stacking method to realize full-thickness regeneration of cartilage, calcified cartilage and subchondral bone. Of note, to surmount the inadequate mechanical property of GelMA hydrogel, nanohydroxyapatite (nHA) was incorporated and further functionalized with hydroxyethyl methacrylate (nHA-hydroxyethyl methacrylate, nHAMA) to enhance the interfacial adhesion with the hydrogel, resulting in better mechanical strength akin to human bone.

View Article and Find Full Text PDF

Motivated by elastography that utilizes tissue mechanical properties as biomarkers for liver disease, with the eventual objective of quantitatively linking histopathology and bulk mechanical properties, we develop a micromechanical modeling approach to capture the effects of fat and collagen deposition in the liver. Specifically, we utilize computational homogenization to convert the microstructural changes in hepatic lobule to the effective viscoelastic modulus of the liver tissue, i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!