During continuous-flow left ventricular assist device (CF-LVAD) support, hemodynamic shear stress causes a burden on aortic valve (AV) leaflets, leading to de novo aortic insufficiency (AI). This study investigated the influence of preoperative hemodynamic parameters on de novo AI in CF-LVAD recipients. We reviewed 125 patients who underwent CF-LVAD implantation without concomitant AV surgery between 2005 and 2018. De novo AI was defined as moderate or severe AI in those with none or trivial preoperative AI. During mean 30 ± 16 months of CF-LVAD support, de novo AI-free rate was 86% and 67% at 1 and 2 years, respectively. Multivariable analysis showed that higher right ventricular stroke work index (RVSWI) (hazard ratio, 1.12 /g/m/beat; 95% confidence interval, 1.00-1.20; p = 0.047) and trivial grade AI (hazard ratio, 2.8; 95% confidence interval, 1.2-6.4; p = 0.020) were independent preoperative risk factors for de novo AI. The longitudinal analysis using generalized mixed effects model showed that higher RVSWI was associated with continuous AV closure after LVAD implantation (Odd ratio, 1.20/g/m/beat; 95% confidence interval, 1.00-1.43 /g/m/beat; p = 0.047). Right heart catheterization revealed that preoperative RVSWI was positively correlated with postoperative pump flow index in patients with continuously closed AV (r = 0.44, p = 0.04, n = 22). Preoperative higher RVSWI was a significant risk factor for de novo AI following CF-LVAD implantation. In patients with preserved right ventricular function, postoperative higher pump flow may affect AI development via hemodynamic stress on the AV.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11345319 | PMC |
http://dx.doi.org/10.1007/s10047-023-01411-1 | DOI Listing |
Heliyon
January 2025
Faculty of Medicine and Medical Sciences, University of Balamand, Kalhat, Lebanon.
Background: Transvenous pacemakers (TVP) and leadless pacemakers (LP) are two reliable permanent modalities for the treatment of heart rhythm disorders. Several observational studies explored the safety and efficacy of the two devices. The aim of this meta-analysis study is to present a comparative analysis of the safety of leadless versus transvenous pacemakers.
View Article and Find Full Text PDFBackground: Diabetic kidney disease (DKD) is one of the typical complications of type 2 diabetes (T2D), with approximately 10 % of DKD patients experiencing a Rapid decline (RD) in kidney function. RD leads to an increased risk of poor outcomes such as the need for dialysis. Albuminuria is a known kidney damage biomarker for DKD, yet RD cases do not always show changes in albuminuria, and the exact mechanism of RD remains unclear.
View Article and Find Full Text PDFAm J Prev Cardiol
March 2025
School of Population Medicine and Public Health, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia around the world with an increased risk of a broad spectrum of adverse comorbidities and death. Whether cardiovascular health (CVH) is associated with AF development remains unclear.
Methods: 238,420 participants without cardiovascular disease at baseline were selected from the UK Biobank study cohort from 2006 to 2010.
Am J Prev Cardiol
March 2025
Department of Cardiology, Hangzhou TCM Hospital Affiliated to Zhejiang Chinese Medical University, Hangzhou, Zhejiang, PR China.
Background And Aims: Atherosclerotic cardiovascular disease (ASCVD) is a leading cause of mortality, and while the association between the urinary albumin-to-creatinine ratio (UACR) and cardiovascular risk is recognized, the specific impact of UACR on the long-term survival of ASCVD patients remains not fully understood. The aim of this study is to investigate the influence of UACR on the long-term risk of all-cause mortality in patients with ASCVD.
Methods: This study included ASCVD patients from the National Health and Nutrition Examination Survey (NHANES) from 1999 to 2018.
Osteoarthr Cartil Open
March 2025
Graduate School of Health Sciences, Morinomiya University of Medical Sciences, Osaka, Japan.
Objective: To investigate whether there is a difference in hardness and hemoglobin concentration changes in the infrapatellar fat pad (IFP) during isometric quadriceps exercise (IQE) in patients with knee osteoarthritis (KOA) between those with and without knee extension limitation.
Design: In this cross-sectional study, data were collected at an orthopedic clinic from March 2022 to April 2023. Among patients diagnosed with KOA, those with knee joint extension range of motion <0° and >0° were defined as the limited group (n = 16) and non-limited group (n = 13), respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!