Purpose: Saphenous vein grafts (SVGs) sometimes occur as vein graft stenosis or failure in coronary artery bypass grafting. The purpose of this study was to detect the factors affecting vein graft atherosclerosis.

Methods: We performed two analysis. In the first analysis, we enrolled 120 grafts using conventionally harvested saphenous vein graft (C-SVG) and followed-up with multiple coronary computed tomography angiography (CCTA). We examined the factors that contribute to the graft atherosclerosis defined by graft failure at subsequent CCTA or substantial progression of graft stenosis (a decrease of ≥0.6 mm in diameter). In the second analysis, 66 grafts using no-touch harvested saphenous vein graft (N-SVG) were compared with those in the first analysis using C-SVG, focusing on the differences in intraoperative factors using propensity score-matched analysis.

Results: In the first analysis, graft atherosclerosis+ group comprised 27 grafts, which had a larger SVG diameter, lower graft velocity, and higher graft/native ratio in diameter than the graft atherosclerosis- group. In the multivariable analysis, slow graft velocity and graft/native ≥2 in diameter were independently associated with the graft atherosclerosis. In the second analysis, the N-SVG group had a much greater graft velocity than the C-SVG group.

Conclusion: Lower graft velocity and higher graft/native ratio in diameter were associated with the graft atherosclerosis. The N-SVG group had increased graft velocity, which may contribute to prevent the graft atherosclerosis.(Trial registration: UMIN Clinical Trial Registry no. UMIN000050482. Registered 3 March 2023, retrospectively registered.).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10902658PMC
http://dx.doi.org/10.5761/atcs.oa.23-00066DOI Listing

Publication Analysis

Top Keywords

graft velocity
24
vein graft
20
graft
18
saphenous vein
16
graft atherosclerosis
16
coronary artery
8
artery bypass
8
bypass grafting
8
grafting purpose
8
graft stenosis
8

Similar Publications

Saphenous Nerve Sensory Assessment in CABG Patients with Great Saphenous Vein Grafts: A Pre and Post Operative Study.

Mymensingh Med J

January 2025

Dr Hitha Antony, Post Graduation 3rd Year Student, Department of Physiology, All India Institute Of Medical Science (AIIMS), Bhopal, India; E-mail:

To assess and compare the sensory component of the saphenous nerve in Coronary artery disease (CAD) patients undergoing Coronary artery bypass graft (CABG) with great saphenous vein graft pre and post-CABG. An observational longitudinal study evaluating the effect of surgery on the saphenous nerve involved 32 CAD patients undergoing CABG. This study was carried out jointly by the Department of Physiology and the Department of Cardiothoracic Vascular Surgery (CTVS) at All India Institute of Medical Sciences, Bhopal, India from November 2022 to January 2024.

View Article and Find Full Text PDF

Perfusion Pressures and Weight Loss During Normothermic Machine Perfusion of Human Donor Livers.

Artif Organs

December 2024

Department of Surgery, Section of Hepatobiliary Surgery and Liver Transplantation, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.

Background: Normothermic machine perfusion (NMP) is increasingly used to preserve and assess donor livers prior to transplantation. Due to its success, it is expected that more centers will start using this technology. However, NMP may also cause adverse effects.

View Article and Find Full Text PDF

Background: To date, no specific treatment has been established to reverse progressive chronic kidney disease (CKD).

Aim: To evaluate the safety and efficacy of autologous CD34 cell transplantation in CKD patients who exhibited a progressive decline in renal function.

Methods: The estimated glomerular filtration rate (eGFR) at the beginning of the study was 15.

View Article and Find Full Text PDF

Intraluminal prosthetic graft thrombus (IPT) has been described in case of endovascular aortic pathology repair. This study aimed to assess hemodynamic indicators associated with various anatomical morphologies following endovascular aortic repair (EVAR), aiming to offer further references for the choice of clinical therapy. Six model models (normal, iliac compression, aortic compression, aortoiliac compression, iliac distortion, and long-leg stent) were established based on common anatomical morphologies following EVAR.

View Article and Find Full Text PDF

Computational exploration of injection strategies for improving medicine distribution in the liver.

Comput Biol Med

December 2024

Faculty of Chemical & Petroleum Engineering, University of Tabriz, Tabriz, Iran. Electronic address:

Background And Objectives: The liver, a vital metabolic organ, is always susceptible to various diseases that ultimately lead to fibrosis, cirrhosis, acute liver failure, chronic liver failure, and even cancer. Optimal and specific medicine delivery in various diseases, hepatectomy, shunt placement, and other surgical interventions to reduce liver damage, transplantation, optimal preservation, and revival of the donated organ all rely on a complete understanding of perfusion and mass transfer in the liver. This study aims to simulate the computational fluid dynamics of perfusion and the temporal-spatial distribution of a medicine in a healthy liver to evaluate the hemodynamic characteristics of flow and medicine transport with the purpose of more effective liver treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!