Aortic annuloplasty has been clearly demonstrated to have a protective influence in aortic valve repair. Over the past 20 years, different annuloplasty concepts have been proposed by different groups. However, the most appropriate approach to enable long-term annular stability remains highly controversial. The aim of this article is to give a general overview of all types of aortic annuloplasty, particularly focusing on the use of an external Teflon ring, as proposed by our group. In this technique, external root dissection is performed in the same fashion as for reimplantation; the only difference is that it is necessary to go below the coronary ostia take-off. A series of pledgeted sutures (usually between 6 and 9 sutures) are placed at the level of the virtual basal ring. The external ring is made using a Teflon strip with a length of 8 to 9 cm, to reduce the annulus to a diameter of between 21 and 23 mm. The sub-annular sutures are then passed at the appropriate level through the Teflon strip and the strip is parachuted outside the aortic root base, passing under the coronary ostia. The two ends of the Teflon strip are tied at the level of the non-coronary sinus. Aortic annuloplasty is a crucial step to improve valve competence and stabilization. While several techniques offer good mid- to long-term results, annuloplasty with an external Teflon ring appears to be a simple and effective alternative to guarantee stable root diameters. Longer follow-up studies are needed to confirm the mid- to long-term results.

Download full-text PDF

Source
http://dx.doi.org/10.52198/23.STI.42.CV1679DOI Listing

Publication Analysis

Top Keywords

aortic annuloplasty
16
external teflon
12
teflon ring
12
teflon strip
12
coronary ostia
8
mid- long-term
8
aortic
6
teflon
6
external
5
ring
5

Similar Publications

Background: Repair of the regurgitant bicuspid aortic valve is an attractive alternative to valve replacement. Although good long-term outcomes have been reported, postoperative aortic stenosis remains a major late cause of repair failure in bicuspid aortic valves. Sinus plication is effective for creating a more symmetrical commissural angle, leading to a decrease in the mean transvalvular pressure gradient.

View Article and Find Full Text PDF

We report a case of a woman who underwent mitral ring and tricuspid annuloplasty. Two months later, she presented with acute heart failure secondary to severe aortic regurgitation, which was a complication of the cardiac surgery. Given the high surgical risk of reoperation in this the patient, she underwent transcatheter aortic valve implantation, with a good result.

View Article and Find Full Text PDF

A 70-year-old man presented to our hospital with chest discomfort and epigastric pain. Echocardiography revealed a giant atrial myxoma in the right atrium with severe tricuspid regurgitation. The aortic valve was calcified, and severe aortic stenosis was observed.

View Article and Find Full Text PDF

Lower mini-sternotomy: an approach for treating all valvulopathies?

Ann Thorac Surg

December 2024

Sorbonne University, Department of Cardiovascular and Thoracic Surgery, Institute of Cardiology, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.

Background: Lower mini-sternotomy offers the advantage of providing excellent visualization of the 4 cardiac cavities, allowing surgical treatment of aortic, mitral and tricuspid valves as well as any intra-cavitary procedure. Technical issues, as well as safety and echocardiographic results of this approach, are lacking. The aim of this retrospective study was to describe outcomes of lower mini-sternotomy to treat valvulopathies and other intracardiac surgeries.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!