Audience: This procedure training model is designed for all levels of emergency medicine residents.
Background: Pericardiocentesis is a relatively uncommon but potentially life-saving procedure within the scope of Emergency Medicine practice. As such, the Accreditation Council for Graduate Medical Education (ACGME) designates its competency as a requirement within emergency medicine residency programs. Because of its relative rarity, simulation-based training is often utilized to fill the gaps in clinical experience during emergency medicine residency training. There have been several models of pericardiocentesis training, including gel-based models that can be purchased or constructed,1-3 non-gel models,4 and cadaveric models.5 In this paper, we describe the fabrication of a high-fidelity cadaveric model and report emergency medicine resident experience with this model. Training programs can use this model to increase trainee competence and confidence with this high-acuity, low-frequency procedure.
Educational Objectives: By the end of this session, residents will gain increased procedural competence and confidence with pericardiocentesis. Residents will be able to identify necessary supplies for the procedure, identify relevant surface anatomy and ultrasound views, and successfully aspirate fluid from model effusion.
Educational Methods: We created a pericardial effusion in a soft prep cadaver by placing a catheter into the pericardial sac and then infusing normal saline via intravenous fluid tubing. Learners were then able to practice aspiration of pericardial fluid via landmark and ultrasound-guided approaches under observation by facilitators able to offer real-time feedback.
Research Methods: Learners were asked to complete a survey assessing pre-intervention and post-intervention subjective confidence in their ability to perform pericardiocentesis and were asked for qualitative feedback on the experience of using the training model.
Results: All residents were able to successfully visualize the pericardial effusion and perform needle aspiration via parasternal and subxiphoid approaches under dynamic ultrasound guidance, allowing needle visualization. All residents reported a subjective increase in procedural confidence and competence after practicing with this training model.
Discussion: Overall, the primary benefit of this training model cited by emergency medicine residents was that it closely approximates reality. This model is re-usable, relatively durable, and reproducible. Emergency medicine residencies associated with academic medical centers that already utilize cadavers for education may relatively easily incorporate this training model into their procedure training curriculum.
Topics: Pericardiocentesis, simulation, task trainer.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10332682 | PMC |
http://dx.doi.org/10.21980/J87930 | DOI Listing |
Ann Emerg Med
January 2025
Division of Medical Toxicology, University of Pittsburgh School of Medicine, Pittsburgh, PA.
Study Objective: The osmol gap can help detect and manage those with toxic alcohol exposure, and it is altered by all alcohols including ethanol. The optimal correction for ethanol that would allow accurate detection of an alternative alcohol is unclear.
Methods: We conducted a prospective cohort study to assess baseline variations in osmol gap, and then to assess the validity of 2 commonly used coefficients (correction factors) for ethanol.
Ann Emerg Med
January 2025
Northwell Health, New Hyde Park, NY; Department of Emergency Medicine, North Shore University Hospital, Manhasset, NY; Department of Emergency Medicine, Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY.
Ann Emerg Med
January 2025
Department of Emergency Medicine, The Warren Alpert Medical School of Brown University, Providence, RI.
J Infect Dev Ctries
December 2024
Department of Pulmonary and Respiratory Medicine, Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia.
Introduction: This study aimed to analyze the levels of MMP-9 and TIMP-1 as biomarkers for identifying lung anatomical and functional abnormalities in coronavirus disease 2019 (COVID-19).
Methodology: Adult COVID-19 patients hospitalized between October and December 2021 were included in the study. MMP-9 and TIMP-1 levels were measured from the blood.
J Infect Dev Ctries
December 2024
Department of Emergency Medicine, Faculty of Medicine, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.
Introduction: Since the dawn of the new millennium, Candida species have been increasingly implicated as a cause of both healthcare-associated as well as opportunistic yeast infections, due to the widespread use of indwelling medical devices, total parenteral nutrition, systemic corticosteroids, cytotoxic chemotherapy, and broad-spectrum antibiotics. Candida tropicalis is a pathogenic Candida species associated with considerable morbidity, mortality, and drug resistance issues on a global scale.
Methodology: We report a case of a 43-year-old man who was admitted to our hospital for further management of severe coronavirus disease 2019 (COVID-19) pneumonia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!