A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Imaging quality of the robotic visualization 4K3D system and its application in microscopic vasectomy reversal in rats]. | LitMetric

Objective: To quantitatively assess the performance of the new robotic visualization system (Zeiss, KINEVO 900) in terms of visual imaging effect and evaluate its potential application in microscopic vasectomy reversal.

Methods: We made a parallel comparison between the effects of the plane and stereo visual images of KINEVO 900 and optical surgical microscopy (Zeiss, S7), and performed microscopic vasectomy reversal on the rat model using KINEVO 900.

Results: Compared with S7, KINEVO 900 provided an even longer working distance (200-625 mm), a 3-4 times larger effective field area and a 1.5-2 times deeper front depth of field with the same working distance of 200 mm. No statistically significant difference was observed in the average anastomosis time and immediate patency rate between the two platforms (P > 0.05).

Conclusion: The 4K3D video image stream outputted by KINEVO 900 is not inferior to that of the optical surgical microscope represented by S7 and is sufficient for microsurgeries in urology and andrology. More prospective randomized clinical animal experiments are needed to further evaluate its application value in andrology.

Download full-text PDF

Source

Publication Analysis

Top Keywords

kinevo 900
16
microscopic vasectomy
12
robotic visualization
8
application microscopic
8
vasectomy reversal
8
optical surgical
8
working distance
8
kinevo
5
[imaging quality
4
quality robotic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!